This paper describes a new approach for the determination of amitriptyline in wastewater by ionic liquid based immersed droplet microextraction (IL-IDME) prior to high-performance liquid chromatography with ultraviolet detection. 1-Hexyl-3-methylimidazolium hexafluorophosphate ([C6MIM][PF6]) was used as an ionic liquid. Various factors that affect extraction, such as volume of ionic liquid, stirring rate, extraction time, pH of the aqueous solution and salting effect, were optimized. The optimal conditions were as follows: microextraction time, 10 min; stirring rate, 720 rpm; pH, 11; ionic drop volume, 100 μL; and no sodium chloride addition. In quantitative experiments the method showed linearity in a range from 0.01 to 10 μg/mL, a limit of detection of 0.004 μg/mL and an excellent pre-concentration factor (PF) of 1100. Finally, the method was successfully applied to the determination of amitriptyline in the hospital wastewater samples.
We synthesized a titanium dioxide-polyaniline core-shell nanocomposite and implemented it as an efficient sorbent for the needle-trap extraction of some volatile organic compounds from urine samples. Polyaniline was synthesized, in the form of the emeraldine base, dissolved in dimethyl acetamide followed by diluting with water at pH 2.8, using the interfacial polymerization method. The TiO nanoparticles were encapsulated inside the conducting polymer shell, by adapting the in situ dispersing approach. The surface characteristics of the nanocomposite were investigated by Fourier transform infrared spectrometry, scanning electron microscopy, and transmission electron microscopy. After obtaining acceptable preliminary results, some selected volatile compounds, including chloroform, benzene, toluene, ethylbenzene, xylene, and chlorobenzenes were used as model analytes to validate the enrichment properties of the prepared sorbent in conjunction with gas chromatography mass spectrometric detection. Important parameters influencing the extraction process such as extraction temperature, ionic strength, sampling flow rate, extraction time, desorption temperature, and time were optimized. The limits of detection and limits of quantification values were in the range of 0.5-3 and 2-5 ng/L, respectively, using time-scheduled selected ion monitoring mode. The relative standard deviation percent with three replicates was in the range of 5-10%. The applicability of the developed needle-trap method was examined by analyzing urine samples and the relative recovery percentages for the spiked samples were in the range of 81-105%.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.