Guidelines discourage continuous pulse oximetry monitoring of hospitalized infants with bronchiolitis who are not receiving supplemental oxygen. Excess monitoring is theorized to contribute to increased alarm burden, but this burden has not been quantified. We evaluated admissions of 201 children (aged 0-24 months) with bronchiolitis. We categorized time ≥60 minutes following discontinuation of supplemental oxygen as “continuously monitored (guideline-discordant),” “intermittently measured (guideline-concordant),” or “unable to classify.” Across 4402 classifiable hours, 77% (11,101) of alarms occurred during periods of guideline-discordant monitoring. Patients experienced a median of 35 alarms (interquartile range [IQR], 10-81) during guideline-discordant, continuously monitored time, representing a rate of 6.7 alarms per hour (IQR, 2.1-12.3). In comparison, the median hourly alarm rate during periods of guideline-concordant intermittent measurement was 0.5 alarms per hour (IQR, 0.1-0.8). Reducing guideline-discordant monitoring in bronchiolitis patients would reduce nurse alarm burden.
Using continuous pulse oximetry (cSpO 2 ) to monitor children with bronchiolitis who are not receiving supplemental oxygen is a form of medical overuse. In this longitudinal analysis from the Eliminating Monitor Overuse (EMO) study, we aimed to assess changes in cSpO 2 overuse before, during, and after intensive cSpO 2deimplementation efforts in six hospitals. Monitoring data were collected during three phases: "P1" baseline, "P2" active deimplementation (all sites engaged in education and audit and feedback strategies), and "P3" sustainment (a new baseline measured after strategies were withdrawn). Two thousand and fifty-three observations were analyzed. We found that each hospital experienced reductions during active deimplementation (P2), with overall adjusted cSpO 2 overuse decreasing from 53%, 95% confidence interval (CI): (49-57) to 22%, 95% CI:(19-25) between P1 and P2. However, following the withdrawal of deimplementation strategies, overuse rebounded in all six sites, with overall adjusted cSpO 2 overuse increasing to 37%, 95% CI: (33-41) in P3.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.