Background: Pollen are monitored in Europe by a network of about 400 pollen traps, all operated manually. To date, automated pollen monitoring has only been feasible in areas with limited variability in pollen species. There is a need for rapid reporting of airborne pollen as well as for alleviating the workload of manual operation. We report our experience with a fully automated, image recognition-based pollen monitoring system, BAA500. Methods: The BAA500 sampled ambient air intermittently with a 3-stage virtual impactor at 60 m3/h in Munich, Germany. Pollen is deposited on a sticky surface that was regularly moved to a microscope equipped with a CCD camera. Images of the pollen were constructed and compared with a library of known samples. A Hirst-type pollen trap was operated simultaneously. Results: Over 480,000 particles sampled with the BAA500 were both manually and automatically identified, of which about 46,000 were pollen. Of the automatically reported pollen, 93.3% were correctly recognized. However, compared with manual identification, 27.8% of the captured pollen were missing in the automatic report, with most reported as unknown pollen. Salix pollen grains were not identified satisfactorily. The daily pollen concentrations reported by a Hirst-type pollen trap and the BAA500 were highly correlated (r = 0.98). Conclusions: The BAA500 is a functional automated pollen counter. Its software can be upgraded, and so we expected its performance to improve upon training. Automated pollen counting has great potential for workload reduction and rapid online pollen reporting.
We studied the cytokines IL(interleukin)-1 beta, IL-4, IL-6 and IL-8 in nasal lavage samples from 20 patients with naturally acquired viral rhinitis and 5 healthy controls without nasal complaints. IL-1 beta, IL-6 and IL-8 levels in lavage fluid from the viral rhinitis patients were significantly elevated when compared to control subjects. IL-4 was not measurable in any of the samples. The cytokine levels in secretions from the healthy controls remained stable intraindividually on 5 consecutive sampling days. We suggest that cytokines such as IL-1 beta, IL-6 and IL-8, but not IL-4, are involved in the pathophysiology of the common cold.
This guideline on diagnostic procedures for suspected beta-lactam antibiotic (BLA) hypersensitivity was written by the German and Austrian professional associations for allergology, and the Paul-Ehrlich Society for Chemotherapy in a consensus procedure according to the criteria of the German Association of Scientific Medical
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.