Acidogenic bacteria within dental plaque biofilms are the causative agents of caries. Consequently, maintenance of a healthy oral environment with efficient biofilm removal strategies is important to limit caries, as well as halt progression to gingivitis and periodontitis. Recently, a novel cleaning device has been described using an ultrasonically activated stream (UAS) to generate a cavitation cloud of bubbles in a freely flowing water stream that has demonstrated the capacity to be effective at biofilm removal. In this study, UAS was evaluated for its ability to remove biofilms of the cariogenic pathogen Streptococcus mutans UA159, as well as Actinomyces naeslundii ATCC 12104 and Streptococcus oralis ATCC 9811, grown on machine-etched glass slides to generate a reproducible complex surface and artificial teeth from a typodont training model. Biofilm removal was assessed both visually and microscopically using high-speed videography, confocal scanning laser microscopy (CSLM), and scanning electron microscopy (SEM). Analysis by CSLM demonstrated a statistically significant 99.9% removal of S. mutans biofilms exposed to the UAS for 10 s, relative to both untreated control biofilms and biofilms exposed to the water stream alone without ultrasonic activation (P < 0.05). The water stream alone showed no statistically significant difference in removal compared with the untreated control (P = 0.24). High-speed videography demonstrated a rapid rate (151 mm(2) in 1 s) of biofilm removal. The UAS was also highly effective at S. mutans, A. naeslundii, and S. oralis biofilm removal from machine-etched glass and S. mutans from typodont surfaces with complex topography. Consequently, UAS technology represents a potentially effective method for biofilm removal and improved oral hygiene.
Summary Biofilms are thin layers of bacteria embedded within a slime matrix that live on surfaces. They are ubiquitous in nature and responsible for many medical and dental infections, industrial fouling and are also evident in ancient fossils. A biofilm structure is shaped by growth, detachment and response to mechanical forces acting on them. The main contribution to biofilm versatility in response to physical forces is the matrix that provides a platform for the bacteria to grow. The interaction between biofilm structure and hydrodynamics remains a fundamental question concerning biofilm dynamics. Here, we document the appearance of ripples and wrinkles in biofilms grown from three species of bacteria when subjected to high‐velocity fluid flows. Linear stability analysis suggested that the ripples were Kelvin–Helmholtz Instabilities. The analysis also predicted a strong dependence of the instability formation on biofilm viscosity explaining the different surface corrugations observed. Turbulence through Kelvin–Helmholtz instabilities occurring at the interface demonstrated that the biofilm flows like a viscous liquid under high flow velocities applied within milliseconds. Biofilm fluid‐like behavior may have important implications for our understanding of how fluid flow influences biofilm biology since turbulence will likely disrupt metabolite and signal gradients as well as community stratification.
Using high-speed imaging we assessed Streptococcus mutans biofilm-fluid interactions during exposure to a 60-ms microspray burst with a maximum exit velocity of 51m/s. S. mutans UA159 biofilms were grown for 72h on 10mm-length glass slides pre-conditioned with porcine gastric mucin. Biofilm stiffness was measured by performing uniaxial-compression tests. We developed an in-vitro interproximal model which allowed the parallel insertion of two biofilm-colonized slides separated by a distance of 1mm and enabled high-speed imaging of the removal process at the surface. S. mutans biofilms were exposed to either a water microspray or an air-only microburst. High-speed videos provided further insight into the mechanical behaviour of biofilms as complex liquids and into high-shear fluid-biofilm interaction. We documented biofilms extremely transient fluid behaviour when exposed to the high-velocity microsprays. The presence of time-dependent recoil and residual deformation confirmed the pivotal role of viscoelasticity in biofilm removal. The air-only microburst was effective enough to remove some of the biofilm but created a smaller clearance zone underlying the importance of water and the air-water interface of drops moving over the solid surface in the removal process. Confocal and COMSTAT analysis showed the high-velocity water microspray caused up to a 99.9% reduction in biofilm thickness, biomass and area coverage, within the impact area.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.