In this work, a high repetition rate laser matrix-assisted laser desorption/ionization (MALDI) source is studied on a quadrupole-time-of-flight (QqTOF) and a triple quadrupole (QqQ) mass spectrometer for rapid quantification of small pharmaceutical drugs. The high repetition rate laser allows an up to 100-fold higher pulse frequency as compared with regular MALDI lasers, resulting in much larger sample throughput and number of accumulated spectra. This increases the reproducibility of signal intensities considerably, with average values being around 5% relative standard deviation after taking into account the area ratio of the analyte to an internal standard. Experiments were conducted in MS/MS mode to circumvent the large chemical background due to MALDI matrix ions in the low mass range. The dynamic range of calibration curves on the QqTOF mass spectrometer extended over at least two orders of magnitude, whereas on the QqQ it extended over at least three orders of magnitude. Detection limits ranged from 60-400 pg/microL on the QqTOF and from 6-70 pg/microL on the QqQ for a series of benzodiazepines. The benzodiazepine content of commercial pill formulations was quantified, and less than 5% error was obtained between the present method and the manufacturer's certified values. Furthermore, a high sample throughput was achieved with this method, so that a single MALDI spot could be quantitatively scanned in as little as 15 s, and an entire 96-well MALDI plate in 24 min.
Spot size reduction and increased detection sensitivity in matrix-assisted laser desorption/ionisation (MALDI) of small molecules are accomplished by using an inexpensive and removable hydrophobic coating for MALDI targets, based on 3M Scotch Gard surface treatment. Several variations in sample preparation were explored, such as surface coating technique, identity of the matrix, solvent composition, and the type of metal support plate used. These were investigated on both uncoated and coated surfaces and their impact on spot size, crystal coverage, and sensitivity is presented here. Additionally, crystallisation behaviour obtained on coated plates is compared with that on uncoated plates using scanning electron microscope analysis. To demonstrate the potential of the new coating technique, erythromycin A and valinomycin are studied to determine the increase in detection sensitivity of coated plates in comparison to uncoated plates, and to reveal the suitability of the plates for application in combined high-performance liquid chromatography/MALDI (HPLC/MALDI), where widely varying solvent compositions and droplet volumes are observed. It is shown that enhancements in detection sensitivities correlate very well with the achieved spot size reduction. The versatility of the coated plates is also exhibited by the ease of removing the surface layer, after which the plates can be rigorously cleaned without worry about damaging the hydrophobic surface, followed by a quick reapplication of new hydrophobic coating material. This makes the non-polar coating superior to more expensive commercial hydrophobic-coated targets, which are much more delicate to clean. Furthermore, cleaning and reapplication eliminate potential carry-over effects and the easy application procedure also makes the fabrication of inexpensive, disposable MALDI targets readily possible.
In this report, the mass spectral analysis of azaspiracid biotoxins is described. Specifically, the collision-induced dissociation (CID) behavior and differences between CID spectra obtained on a triple-quadrupole, a quadrupole time-of-flight, and an ion-trap mass spectrometer are addressed here. The CID spectra obtained on the triple-quadrupole mass spectrometer allowed the classification of the major product ions of the five investigated compounds (AZA 1-5) into five distinct fragment ion groups, according to the backbone cleavage positions. Although the identification of unknown azaspiracids was difficult based on CID alone, the spectra provided sufficient structural information to allow confirmation of known azaspiracids in marine samples. Furthermore, we were able to detect two new azaspiracid analogs (AZA 1b and 6) in our samples and provide a preliminary structural analysis. The proposed dissociation pathways under tandem mass spectrometry (MS/MS) conditions were confirmed by a comparison with accurate mass data from electrospray quadrupole time-of-flight MS/MS experiments. Regular sequential MS(n) analysis on an ion-trap mass spectrometer was more restricted in comparison to the triple-quadrupole mass spectrometer, because the azaspiracids underwent multiple [M + H - nH(2)O](+) (n = 1-6) losses from the precursor ion under CID. Thus, the structural information obtained from MS(n) experiments was somewhat limited. To overcome this limitation, we developed a wide-range excitation technique using a 180-u window that provided results comparable to the triple-quadrupole instrument. To demonstrate the potential of the method, we applied it to the analysis of degraded azaspiracids from mussel tissue extracts.
This study describes the application of a novel, reactive matrix for the mass spectral analysis of steroids by capillary-high performance liquid chromatography (capillary-HPLC) coupled to matrix-assisted laser desorption/ionization (MALDI). The mass spectral analysis of steroids was accomplished after fully automated peak deposition of chromatographic peaks onto MALDI targets. The seven corticosteroids used as test compounds were: triamcinolone, prednisone, cortisone, fludrocortisone, dexamethasone, deoxycorticosterone, and budesonide. They were separated using a PepMap C(18) (3 microm particle size, 100 A pore width) column at five different concentration levels of 25, 15, 7.5, 2.5 and 1 ng/microL, and the peaks were detected at a wavelength of 237 nm. The column effluent was mixed with 2,4-dinitrophenylhydrazine (DNPH) directly following the UV detector. The chromatographic peaks were then deposited onto the MALDI target with a robotic micro-fraction collector triggered by the UV detector signals. A special hydrophobic surface coating allowed the deposition of up to 4 microL (up to 90 % of the chromatographic peak volume) onto one sample spot. The compounds were then identified by MALDI mass spectrometry. Depending on the nature of the analyte, radical cations ([M](+.)) and sodium adduct ions ([M+Na](+)) of the steroids as well as protonated steroid-dinitrophenylhydrazone derivatives ([M(D)+H](+)) were detected in positive ion mode. The detection limits were between 0.5 and 15 ng injected with capillary-HPLC-MALDI-TOF-MS and between 0.3 and 3 ng on target with MALDI-TOF when deposited manually.
In this study, the performance of monolithic columns was evaluated for ultrafast liquid chromatography/mass spectrometry (LC/MS) analyses and for high-resolution separations of several azaspiracid biotoxin analogs. Because of their high permeability, monolithic columns offer a number of advantages over conventional packed columns; viz., very low backpressures and relatively flat van Deemter curves at high flow rates. That is, very high flow rates can be used for ultrafast analyses or, by using longer than normal columns, high-resolution separations are possible. In a series of experiments, we varied the mobile phase flow rates between 1 and 8 mL/min, and studied their impact on chromatographic parameters such as retention time, resolution, number of plates and pressure. The chromatographic run times could be reduced to ca. 30 s without a significant change in the separation efficiency. A signal intensity comparison revealed interesting differences between atmospheric-pressure chemical ionization (APCI) and electrospray ionization (ESI) in their flow-rate dependency. An explanation with respect to the behavior as of a mass-flow or a concentration-dependent device is given in the paper. Additionally, the column length was varied between 10 and 70 cm. As a result, the number of theoretical plates increased substantially. In the example shown in the report, an increase from 13 000 plates for a 10-cm column to 80 000 for a 70-cm column is demonstrated. In addition, the potential of the monolithic columns for high-resolution LC/MS separations is shown for a complex biotoxin mixture, which was separated on a 40-cm-long column.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.