Aims
Atrial fibrillation (AF) is frequently observed in hypertrophic cardiomyopathy (HCM) and is associated with poor clinical outcome. Total atrial conduction time, estimated by tissue Doppler imaging (TDI), the so-called PA-TDI duration, reflects the left atrial (LA) structural and electrical remodelling. The aim of this study was to evaluate the association between PA-TDI and new-onset AF in patients with HCM.
Methods and results
From a large cohort of patients with HCM, 208 patients (64% male, mean age 53 ± 14 years) without AF were selected. PA-TDI duration was measured from the onset P wave on electrocardiogram to the peak A′ wave of the lateral LA wall using TDI. The incidence of new-onset AF was 20% over a median follow-up of 7.3 (3.5–10.5) years. Patients with incident AF had longer PA-TDI duration when compared with patients without AF (133.7 ± 23.0 vs. 110.5 ± 30.0 ms, P < 0.001). PA-TDI duration was independently associated with new-onset AF (hazard ratio: 1.03, 95% confidence interval: 1.01–1.05, P < 0.001).
Conclusion
Prolonged PA-TDI duration was independently associated with new-onset AF in patients with HCM. This novel parameter could be useful to risk-stratify patients with HCM who are at risk of having AF.
The aim of this study is to evaluate the agreement between three-dimensional (3D) transesophageal echocardiography (TEE) and multidetector computed tomography (MDCT) for assessing mitral annular (MA) dimensions. A total of 105 patients (79 ± 9 years old, 52% male) who underwent clinically indicated 3D TEE and MDCT feasible for MA geometrical assessment were included. Using dedicated semi-automated postprocessing software, MA geometry, including mitral annular area (MAA), perimeter, septal-lateral (SL) diameter, and inter-trigonal (TT) diameter, was evaluated using 3D TEE and MDCT. Compared to 3D TEE, MAA, perimeter, and SL distance measured on MDCT data were larger (9.9 ± 3.0 vs. 9.3 ± 3.1 cm2 for MAA; 115 ± 18 vs. 108 ± 18 mm for perimeter; and 35 ± 5 vs. 32 ± 5 cm for SL distance, all p < 0.001). By contrast, the TT distance was comparable between MDCT and 3D TEE (26 ± 4 vs. 26 ± 4 cm, p = 0.258). The correlations of all the MA dimensions were good to excellent between the two modalities (R = 0.911 for MAA, 0.890 for perimeter, 0.739 for TT distance, and 0.857 for SL distance, respectively, all p < 0.001). This study showed good agreement between 3D TEE- and MDCT-derived MA measurements although MDCT systematically provided larger MAA, perimeter, and SL distance compared with 3D TEE.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.