Analytical method validation provides a means to ensure that data are credible and reproducible. This unit will provide a brief introduction to analytical method validation as applied to cellular analysis by flow cytometry. In addition, the unit will provide practical procedures for three different types of validation. The first is a limited validation protocol that is applicable for research settings and non‐regulated laboratories. The second is validation protocol that presents the minimum validation requirements in regulated laboratories. The third is a transfer validation protocol to be used when methods are transferred between laboratories. The recommendations presented in this unit are consistent with the white papers published by the American Association of Pharmaceutical Scientists and the International Clinical Cytometry Society, as well as with Clinical Laboratory Standards Institute Guideline H62: Validation of Assays Performed by Flow Cytometry (currently in preparation). © 2018 by John Wiley & Sons, Inc.
The CD40/CD40L axis plays a central role in the generation of humoral immune responses and is an attractive target for treating autoimmune diseases in the clinic. Here, we report the generation and clinical results of a CD40L binding protein, VIB4920, which lacks an Fc domain, therefore avoiding platelet-related safety issues observed with earlier monoclonal antibody therapeutics that targeted CD40L. VIB4920 blocked downstream CD40 signaling events, resulting in inhibition of human B cell activation and plasma cell differentiation, and did not induce platelet aggregation in preclinical studies. In a phase 1 study in healthy volunteers, VIB4920 suppressed antigen-specific IgG in a dose-dependent fashion after priming and boosting with the T-dependent antigen, KLH. Furthermore, VIB4920 significantly reduced circulating Ki67+ dividing B cells, class-switched memory B cells, and a plasma cell gene signature after immunization. In a phase 1b proof-of-concept study in patients with rheumatoid arthritis, VIB4920 significantly decreased disease activity, achieving low disease activity or clinical remission in more than 50% of patients in the two higher-dose groups. Dose-dependent decreases in rheumatoid factor autoantibodies and Vectra DA biomarker score provide additional evidence that VIB4920 effectively blocked the CD40/CD40L pathway. VIB4920 demonstrated a good overall safety profile in both clinical studies. Together, these data demonstrate the potential of VIB4920 to significantly affect autoimmune disease and humoral immune activation and to support further evaluation of this molecule in inflammatory conditions.
The current consensus recommendation papers dealing with the unique requirements for the analytical validation of assays performed by flow cytometry address the validation of sensitivity (both analytical and functional) only in general terms. In this paper, a detailed approach for designing and validating the sensitivity of rare event methods is described. The impact of panel design and optimization on the lower limit of quantification (LLOQ) and suggestions for reporting data near, or below, the LLOQ are addressed. This paper serves to provide best practices for the development, optimization, and analytical validation of flow cytometric assays designed to assess rare events. Note that this paper does not discuss clinical sensitivity validation, which addresses the positive and negative predictive value of the test result.
Purpose: Immune checkpoint blockade has demonstrated clinical benefits across multiple solid tumor types; however, resistance and relapse often occur. New immunomodulatory targets, which are highly expressed in activated immune cells, are needed. MEDI0562, an agonistic humanized mAb, specifically binds to the costimulatory molecule OX40. This first-inhuman study evaluated MEDI0562 in adults with advanced solid tumors.Patients and Methods: In this phase I, multicenter, openlabel, single-arm, dose-escalation (3þ3 design) study, patients received 0.03, 0.1, 0.3, 1.0, 3.0, or 10 mg/kg MEDI0562 through intravenous infusion every 2 weeks, until confirmed disease progression or unacceptable toxicity. The primary objective evaluated safety and tolerability. Secondary endpoints included antitumor activity, pharmacokinetics, immunogenicity, and pharmacodynamics.Results: In total, 55 patients received ≥1 dose of MEDI0562 and were included in the analysis. The most common tumor type was squamous cell carcinoma of the head and neck (47%). Median duration of treatment was 10 weeks (range, 2-48 weeks). Treatment-related adverse events (TRAEs) occurred in 67% of patients, most commonly fatigue (31%) and infusion-related reactions (14%). Grade 3 TRAEs occurred in 14% of patients with no apparent dose relationship; no TRAEs resulted in death. Two patients had immune-related partial responses per protocol and 44% had stable disease. MEDI0562 induced increased Ki67 þ CD4 þ and CD8 þ memory T-cell proliferation in the periphery and decreased intratumoral OX40 þ FOXP3 þ cells.Conclusions: MEDI0562 was safely administered at doses up to 10 mg/kg in heavily pretreated patients. On-target pharmacodynamic effects were suggested in this setting. Further evaluation with immune checkpoint inhibitors is ongoing.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.