This paper describes the effects of an 85 0 C/ 85% RH environment on the bond strength of passivated and unpassivated aluminum wire bonds in contact with thick film platinum-silver metallization in a nonhermetic package. An RTV silicone junction coating material and a ceramic cover coated with a single component epoxy resin powder were used singly and in combination to protect the wire bonds. Test samples were exposed to the 85 0 C/85%RH environment for a total period of 168 hours. Bonds were destructively pull tested at the end of 24, 96 and 168 hours. Selected samples were also examined with an optical microscope and a scanning electron microscope (SEM). It was observed that the unencapsulated wire bonds suffered extensive galvanic corrosion at the Al-to-PtAg interface after 24 hours of exposure. The encapsulated bonds had no visible corrosion at the bond sites and retained more than 80% of the initial bond strength even after 168 hours of exposure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.