The high-volume synthesis of two-dimensional (2D) materials in the form of platelets is desirable for various applications. While water is considered an ideal dispersion medium, due to its abundance and low cost, the hydrophobicity of platelet surfaces has prohibited its widespread use. Here we exfoliate 2D materials directly in pure water without using any chemicals or surfactants. In order to exfoliate and disperse the materials in water, we elevate the temperature of the sonication bath, and introduce energy via the dissipation of sonic waves. Storage stability greater than one month is achieved through the maintenance of high temperatures, and through atomic and molecular level simulations, we further discover that good solubility in water is maintained due to the presence of platelet surface charges as a result of edge functionalization or intrinsic polarity. Finally, we demonstrate inkjet printing on hard and flexible substrates as a potential application of water-dispersed 2D materials.
Acoustic wave propagation in bovine cancellous bone is experimentally and theoretically investigated in the frequency range of 0.5-1 MHz. The phase velocity, attenuation coefficient, and broadband ultrasonic attenuation (BUA) of bovine cancellous bone are measured as functions of frequency and porosity. For theoretical estimation, the Modified Biot-Attenborough (MBA) model is employed with three new phenomenological parameters: the boundary condition, phase velocity, and impedance parameters. The MBA model is based on the idealization of cancellous bone as a nonrigid porous medium with circular cylindrical pores oriented normal to the surface. It is experimentally observed that the phase velocity is approximately nondispersive and the attenuation coefficient linearly increases with frequency. The MBA model predicts a slightly negative dispersion of phase velocity linearly with frequency and the nonlinear relationships of attenuation and BUA with porosity. The experimental results are in good agreement with the theoretical results estimated with the MBA model. It is expected that the MBA model can be usefully employed in the field of clinical bone assessment for the diagnosis of osteoporosis.
It is well known that ocean ambient noise levels in the frequency range from a few hundred hertz to several tens of kilohertz are well correlated with wind speed. A physical mechanism that could account for some of this sound generation is the production of bubble clouds by breaking waves. A simple laboratory study of the sound generated by a column of bubbles is reported here. From measurements of the various characteristics of this column, good evidence is obtained that the bubbles within the column are vibrating in a collective mode of oscillation. Based upon an assumption of collective oscillations, analytical calculations of the predicted frequency of vibration of this column as well as the dependence of this frequency on such parameters as bubble population and column geometry agree closely with the measured values. These results give evidence that the bubble plumes generated by breaking waves can be a strong source of relatively low frequency (< 1 kHz) ambient noise.
The efficacy of ultrasound-assisted thrombolysis as an adjunct treatment of ischemic stroke is being widely investigated. To determine the role of ultrasound hyperthermia in the process of blood clot disruption, the acousto-mechanical and thermal properties of clotted blood were measured in vitro, namely, density, speed of sound, frequency-dependent attenuation, specific heat, and thermal conductivity. The amplitude coefficient of attenuation of the clots was determined for 120 kHz, 1.0 MHz, and 3.5 MHz ultrasound at room temperature (20 +/- 2 degrees C). The attenuation coefficient ranged from 0.10 to 0.30 Np/cm in porcine clots and from 0.09 to 0.23 Np/cm in human clots. The experimentally determined values of specific heat and thermal conductivity for porcine clotted blood are (3.2 +/- 0.5) x 10(3) J/kg x K and 0.55 +/- 0.13 W/m x K, respectively, and for human clotted blood are (3.5 +/- 0.8) x 10(3) J/kg x K and 0.59 +/- 0.11 W/m x K, respectively. Measurements of the acousto-mechanical and thermal properties of clotted blood can be helpful in theoretical modeling of ultrasound hyperthermia in ultrasound-assisted thrombolysis and other high-intensity focused ultrasound applications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.