Aims It is increasingly recognised that tools are required for assessing and benchmarking quality of care in order to improve it. The European Society of Cardiology (ESC) is developing a suite of quality indicators (QIs) to evaluate cardiovascular care and support the delivery of evidence-based care. This paper describes the methodology used for their development. Methods and Results We propose a four-step process for the development of the ESC QIs. For a specific clinical area with a gap in care delivery, the QI development process includes: 1) the identification of key domains of care by constructing a conceptual framework of care; 2) the construction of candidate QIs by conducting a systematic review of the literature; 3) the selection of a final set of QIs by obtaining expert opinions using the modified Delphi method; and 4) the undertaking of a feasibility assessment by evaluating different ways of defining the QI specifications for the proposed data collection source. For each of the four steps, key methodological areas need to be addressed to inform the implementation process and avoid misinterpretation of the measurement results. Conclusion Detailing the methodology for the ESC QIs construction enables healthcare providers to develop valid and feasible metrics to measure and improve the quality of cardiovascular care. As such, high-quality evidence may be translated into clinical practice and the ‘evidence-practice’ gap closed.
Background Evidence supports an excess of deaths during the COVID-19 pandemic. We report the incidence and mortality of thrombo-embolic events (TE) during the COVID-19 pandemic. Methods Multi-sourced nationwide cohort study of adults (age ≥18 years) admitted to hospital with TE and deaths from TE in England (hospital and community) between 1st February 2018 and 31st July 2020. Relative risks, adjusted for age, sex, atrial fibrillation, co-morbidities and time trend comparing before and during the COVID-19 pandemic were estimated using Poisson regression. Findings Of 268,054 patients admitted with TE to 195 hospitals, 82,208 (30.6%) were admitted after 2nd March 2020 (first COVID-19 death in the UK). The incidence of TE hospitalised increased during the COVID-19 pandemic from 1090 to 1517 per 100,000 (absolute risk change 45.9% [95% CI 45.1–46.6%], adjusted relative risk [ARR] 1.43 [95% CI 1.41–1.44]) driven particularly by pulmonary embolism; 1.49, 95% CI 1.46–1.52. TE were more frequent among those with COVID-19; 1.9% vs. 1.6%, absolute risk change 21.7%, 95% CI 21.0–22.4%, ARR 1.20, 95% CI 1.18–1.22. There was an increase in the overall mortality from TE during the pandemic (617, 6.7% proportional increase compared with the historical baseline), with more TE deaths occurring in the community compared with the historical rate (44% vs. 33%). Interpretation The COVID-19 pandemic has resulted in an increase in the incidence of hospitalised TE. There were more deaths from TE in the community highlighting a number of mechanisms including the hypercoagulable state associated with COVID-19 infection and potential impact of delays in seeking help. Research in context Evidence before this study We searched PubMed on 16 November 2020 for articles that documented the incidence and mortality of thrombo-embolic events (TE) during the COVID-19 pandemic using the search terms “COVID-19” OR “Coronavirus*” OR “2019-nCOV” OR “SARS-CoV” AND (“Thromboembolism” OR “Venous Thromboembolism” OR “thromboembol*”) with no language or time restrictions. The majority of data on TE in COVID-19 pertains to hospitalised patients from retrospective cohort studies. One study found that TE in hospitalised patients was associated with an increased mortality rate (adjusted hazard ratio 1.82; 95% CI 1.54–2.15). A systematic review and meta-analysis of 35 studies in 9249 hospitalised patients calculated an overall pooled incidence of TE of 17.8% (95% CI: 9.9–27.4%), rising to 22.9% (95% CI: 14.5–32.4%) in patients admitted to intensive care (ICU). The most contemporary data are from a cohort of 1114 patients (715 outpatient, 399 hospitalised, 170 admitted to ICU). With robust COVID-19-specific therapies and widespread thromboprophylaxis the prevalence of venous TE in ICU patients was reported as 7% ( n = 12) when catheter-/device-related events were excluded, and among the outpati...
To develop a suite of quality indicators (QIs) for the evaluation of the quality of care for adults with heart failure (HF).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.