We introduce an ultra-thin attosecond optical delay line based on controlled wavefront division of a femtosecond infrared pulse after transmission through a pair of micrometer-thin glass plates with negligible dispersion effects. The time delay between the two pulses is controlled by rotating one of the glass plates from absolute zero to several optical cycles, with 2.5 as to tens of attosecond resolution with 2 as stability, as determined by interferometric self-calibration. The performance of the delay line is validated by observing attosecond-resolved oscillations in the yield of high harmonics induced by time delayed infrared pulses, in agreement with a numerical simulation for a simple model atom. This approach can be extended in the future for performing XUV-IR attosecond pump–probe experiments.
We demonstrate a dispersion-free wavefront splitting attosecond resolved interferometric delay line for easy ultrafast metrology of broadband femtosecond pulses. Using a pair of knife-edge prisms, we symmetrically split and later recombine the two wavefronts with a few tens of attosecond resolution and stability and employ a single-pixel analysis of interference fringes with good contrast using a phone camera without any iris or nonlinear detector. Our all-reflective delay line is theoretically analyzed and experimentally validated by measuring 1st and 2nd order autocorrelations and the SHG-FROG trace of a NIR femtosecond pulse. Our setup is compact, offers attosecond stability with flexibility for independent beam-shaping of the two arms. Furthermore, we suggest that our compact and in-line setup can be employed for attosecond resolved pump-probe experiments of matter with few-cycle pulses.
We demonstrate a dispersion-free wavefront splitting attosecond resolved interferometric delay line for easy ultrafast metrology of broadband femtosecond pulses. Using a pair of knife-edge prisms, we symmetrically split and later recombine the two wavefronts with a few tens of attosecond resolution and stability and employ a single-pixel analysis of interference fringes with good contrast using a phone camera without any iris or nonlinear detector. Our all-reflective delay line is theoretically analyzed and experimentally validated by measuring 1 st and 2 nd order autocorrelations and the SHG-FROG trace of a NIR femtosecond pulse. Our setup is compact, offers attosecond stability with flexibility for independent beam-shaping of the two arms. Furthermore, we suggest that our compact and in-line setup can be employed for attosecond resolved pump-probe experiments of matter with few-cycle pulses.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.