RDAVR facilitates reduced aortic cross-clamp and cardiopulmonary bypass times compared with standard AVR, particularly in patients undergoing concomitant procedures, allowing the use of larger prostheses and resulting in lower transvalvular gradients and higher indexed effective orifice area compared with standard AVR. Therefore, RDAVR may help to overcome patient-prosthesis mismatch in some patients.
SARS-CoV-2 (COVID-19) infections have been recently shown to be associated with a high rate of thromboembolic events due to pro-coagulative mechanisms that have not yet been fully understood. This paper reports on a 55-year-old female COVID-19 patient with severe ARDS and pulmonary embolism (PE) complicated by cardiogenic shock after 12 days of hospitalization under initial prophylactic anticoagulation with low molecular weight heparin (LMWH). An ultima-ratio va (veno-arterial) ECMO implantation and subsequent rapid upgrade to vvaECMO due to insufficient oxygenation was performed. The patient developed severe coagulopathy with intrapulmonary bleeding. The present report aims to highlight and discuss the pros and cons of various anticoagulation strategies in COVID-19 patients focusing on current scientific debates to address this frequently observed complication in the current situation worldwide.
Background Surgical aortic valve replacement (SAVR) is nowadays discussed whether it remains the gold standard of treatment. In the last decade, there has been a tremendous increase in transcatheter aortic valve implantation (TAVI) due to the growing expertise and excellent results of the catheter-based approach. We, therefore, retrospectively compared the rapid deployment valve (RDV), the Edwards Intuity valve (IEV), with the Edwards Sapien 3 (S3V) with regard to post-procedural hemodynamics.
Methods A total of 246 patients treated with TAVI or SAVR between February 2009 and November 2015 were included. One-hundred twenty-five patients were analyzed in the SAVR group and compared with 121 patients undergoing TAVI. Transvalvular pressure gradients (PGs) and the incidence and extent of aortic regurgitation (AR) were compared post-procedurally by echocardiography for each valve size. In vitro hemodynamics were analyzed by placing both valves into an aortic silicone phantom connected to a pulsatile flow pump and measured using phase-contrast magnetic resonance imaging (4D flow MRI).
Results Post-procedurally, mean transvalvular PGs for the 23 mm valves were 9 (7;11.5) versus 13 (9;18) (p < 0.001), whereas maximum PGs were 16.5 (14;22) versus 25.5 mm Hg (17.5;34) (p < 0.001) in IEV and S3V patients, respectively. The 21 mm IEV showed significantly lower transvalvular PGs compared with the 23 mm S3V: mean PGs: 11 (8;13) versus 13 (9;18) (p < 0.05); maximum PG: 19.5 (13;24) versus 25.5 (18;34) mm Hg (p < 0.05). Analysis revealed significantly lower post-procedural transvalvular PGs for larger valves sizes. With respect to AR, the incidence of AR was significantly lower in IEV group (p < 0.05). In vitro velocities and turbulent kinetic energy values showed similar results between both valves.
Conclusion Implanted RDVs presented a lower incidence of paravalvular regurgitation and were associated with significantly lower post-procedural transvalvular PGs, especially for small valve sizes. Our data might support the application of rapid deployment aortic valves in patients with small aortic annulus in the TAVI era.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.