The present investigation was designed to test cellular toxicity of modern dentin adhesives. With the use of the products Ariston Liner, Etch & Prime 3.0, Optibond Solo, Prime & Bond NT, Scotchbond 1, and Syntac Sprint, test specimens were prepared according to the manufacturers' instructions and transferred into a culture medium. Eluates were obtained and pipetted onto fibroblast cultures, incubated, and subsequently stained. The respective cell densities and the numbers of normal, altered, and dead cells were determined and compared with control cell cultures. Statistical analysis of the data showed that all materials caused cytotoxic effects. Scotchbond 1 displayed the highest number of dead cells. The difference was statistically significant compared to Etch" 3.0, Optibond Solo, Prime&Bond NT, and the control. The lowest cell density was found for Scotchbond 1 and Ariston Liner. The difference was also statistically significant in comparison with Etch" 3.0, Optibond Solo, Prime&Bond NT, and the control. To conclude, all tested dentin adhesives caused cytotoxic reactions. Taking the limitations of an in vitro experiment into consideration, Prime&Bond NT, Optibond Solo, and Etch" 3.0 appear to be the most recommendable products, and Scotchbond 1 and Ariston Liner the least.
This position paper outlines the areas of competence and learning outcomes of "The Graduating European Dentist" that specifically relate to patient-centred care. This approach is becoming increasingly prominent within the literature and within policy documents. Whilst working to an evidence base is critical, dentists must also be aware of the scientific basis that underpins the treatment they provide. The evaluation process, which supports treatment planning, also requires dentists to be able to listen, collate, and record pertinent information effectively. In addition, the ability to account for a patient's social, cultural and linguistic needs (cultural competence) will result in a practitioner who is able to treatment plan for patient-centred care.
Topical application of hydrofluoric acid appeared to provide a dentinal surface with an amorphous precipitate of fluoride. This layer may be important both for resistance of dental caries in dentin and for bonding reactions.
This investigation was designed to test the cellular toxicity of two medicated (Roeko activ point and Roeko Calcium Hydroxide) and four nonmedicated brands of gutta-percha (GP) points (Antaeos, DeTrey White, Roeko color, and Roeko Top color). The test points were transferred into a culture medium including the GP-point material with a concentration of 6 mg/ml, and eluates were obtained after 72 h. Five milliliters of each eluate were pipetted onto fibroblast cultures, incubated, and subsequently stained. Mitotic rates, cell densities, and the distribution of normal cells, pathologically altered and dead cells were determined and correlated with control cell cultures. Roeko activ point (containing chlorhexidine) resulted in the highest number of dead cells. The difference was statistically significant in comparison with all other materials. Concerning all parameters mentioned, the cytotoxicity of the points containing calcium hydroxide (Roeko Calcium Hydroxide) was not significantly different from all other points tested, with the exception of those containing chlorhexidine. All tested gutta-percha materials caused cytotoxic reactions in varying extents. Taking into consideration the limitations of an in vitro experiment, points containing calcium hydroxide and nonmedicated points seem to be the most recommendable products for clinical use.
This in vitro study evaluated the efficacy and safety of six different nickel-titanium engine-driven instruments used with a torque-controlled engine device and nickel-titanium hand and stainless steel hand instruments in preparation of curved canals. A total of 80 curved (36 degrees) simulated root canals were prepared. Images before and after were superimposed, and instrumentation areas were observed. Time of instrumentation, instrument failure, change in working length and weight loss were also recorded. Results show that stainless steel hand instruments cause significantly less transportation towards the inner wall of the canal than do nickel-titanium hand instruments. No instrument fracture occurred with hand instruments, but 30-60% breakage of instruments was recorded during instrumentation with the engine-driven devices. The working length was maintained by all types of instruments. Newly developed nickel-titanium rotary files were not able to prevent straightening of the severely curved canals when a torque-controlled engine-driven device was used.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.