Face mask filters—textile, surgical, or respiratory—are widely used in an effort to limit the spread of airborne viral infections. Our understanding of the droplet dynamics around a face mask filter, including the droplet containment and leakage from and passing through the cover, is incomplete. We present a fluid dynamics study of the transmission of respiratory droplets through and around a face mask filter. By employing multiphase computational fluid dynamics in a fully coupled Eulerian–Lagrangian framework, we investigate the droplet dynamics induced by a mild coughing incident and examine the fluid dynamics phenomena affecting the mask efficiency. The model takes into account turbulent dispersion forces, droplet phase-change, evaporation, and breakup in addition to the droplet–droplet and droplet–air interactions. The model mimics real events by using data, which closely resemble cough experiments. The study shows that the criteria employed for assessing the face mask performance must be modified to take into account the penetration dynamics of airborne droplet transmission, the fluid dynamics leakage around the filter, and reduction of efficiency during cough cycles. A new criterion for calculating more accurately the mask efficiency by taking into account the penetration dynamics is proposed. We show that the use of masks will reduce the airborne droplet transmission and will also protect the wearer from the droplets expelled from other subjects. However, many droplets still spread around and away from the cover, cumulatively, during cough cycles. Therefore, the use of a mask does not provide complete protection, and social distancing remains important during a pandemic. The implications of the reduced mask efficiency and respiratory droplet transmission away from the mask are even more critical for healthcare workers. The results of this study provide evidence of droplet transmission prevention by face masks, which can guide their use and further improvement.
International audienceWe present an experimental approach used to measure both normal stress differences and the particle phase contribution to the normal stresses in suspensions of non-Brownian hard spheres. The methodology consists of measuring the radial profile of the normal stress along the velocity gradient direction in a torsional flow between two parallel discs. The values of the first and the second normal stress differences, and , are deduced from the measurement of the slope and of the origin ordinate. The measurements are carried out for a wide range of particle volume fractions (between 0.2 and 0.5). As expected, is measured to be negative but is found to be positive. We discuss the validity of the method and present numerous tests that have been carried out in order to validate our results. The experimental setup also allows the pore pressure to be measured. Then, subtracting the pore pressure from the total stress, , the contribution of the particles to the normal stress is obtained. Most of our results compare well with the different experimental and numerical data present in the literature. In particular, our results show that the magnitude of the particle stress tensor component and their dependence on the particle volume fraction used in the suspension model balance proposed by Morris & Boulay (J. Rheol., vol. 43, 1999, p. 1213) are suitable
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.