Purpose:The aim of this study was to produce a low-cost anatomical model of adult male including lower limbs to evaluate the three-dimensional dose distribution for dosimetry measurements, especially in total body irradiation (TBI) and total skin electron therapy (TSET).Materials and methods:Computed tomography (CT) scan images of the atomic energy organisation RANDO phantom and lower limb CT scan images of 20 healthy persons were averaged. Selections of different body tissues substitute materials and phantom validation were performed according to previous studies worked on construction of radiation therapy phantoms.Results:The dosimetry aspect of the selected substitute materials from all considered methods showed that they were in good agreement with real human tissue, especially bone, with a percentage error of 0·5%. The results show that the electron densities obtained from the linear attenuation coefficient (reDLAC) for the tissue equivalent material used in the phantom is a better option for validation.Conclusions:This validated phantom has numerous advantages over the origin type of RANDO phantom. Therefore, using it in TBI and TSET dosimetry is recommendable.
BackgroundOne of the stereotactic radiosurgery techniques is Gamma Knife radiosurgery, in which intracranial lesions that are inaccessible or inappropriate for surgery are treated using 201 cobalt-60 sources in one treatment session. In this conformal technique, the penumbra width, which results in out-of-field dose in tumour-adjacent normal tissues should be determined accurately. The aim of this study is to calculate the penumbra widths of single and 201 beams for different collimator sizes of Gamma Knife machine model 4C using EGSnrc/BEAMnrc Monte Carlo simulation code and comparison the results with EBT3 film dosimetry data.Methods and materialsIn this study, simulation of Gamma Knife machine model 4C was performed based on the Monte Carlo codes of EGSnrc/BEAMnrc. To investigate the physical penumbra width (80−20%), the single beam and 201 beams profiles were obtained using EGSnrc/DOSXYZnrc code and EBT3 films located at isocentre point in a spherical Plexiglas head phantom.ResultsBased on the results, the single beam penumbra widths obtained from simulation data for 4, 8, 14 and 18 mm collimator sizes alongXaxis were 0·75, 0·77, 0·90 and 0·92 mm, respectively. The data for 201 beams obtained from simulation were 2·61, 4·80, 7·92 and 9·81 mm alongXaxis and 1·31, 1·60, 1·91 and 2·14 mm alongZaxis and from film dosimetry were 3·21, 4·90, 8·00 and 10·61 mm alongXaxis and 1·22, 1·69, 2·01 and 2·25 mm alongZaxis, respectively.ConclusionThe differences between measured and simulated penumbra widths are in an acceptable range. However, for more precise measurement in the penumbra region in which dose gradient is high, Monte Carlo simulation is recommended.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.