Organic matter is a fundamental component of a substrate. However, different organic matter sources can provide different physiological responses from seedlings as a result of different types and concentrations of humic substances, which influence the functioning of the plant and the structuring of the soil. The objective of this work was to quantify photosynthetic pigments, gas exchange, and secondary metabolite indices in the abaxial and adaxial parts of leaves of Conilon coffee clonal plantlets grown in different sources of organic materials. The experiment was arranged in a randomized block design with five treatments and five replications. The treatments consisted of different sources of organic matter added to the substrate: 85% soil + 15% urban waste compost; 85% soil + 15% mature cattle manure; 85% soil + 15% dairy residue; 85% soil + 15% tannery sludge; and a Control: 100% soil, without addition of organic material. The contents of chlorophylls a, b, and total, carotenoids, and their ratios were analyzed by destructive methods. Indirect measurements of nitrogen and chlorophyll (SPAD) were performed by non-destructive methods. Fluorescence indices of flavonoids, anthocyanins, total chlorophyll, and nitrogen balance were estimated using a Multiplex® sensor. The substrate added with dairy residue provided the highest chlorophyll a production in the adaxial part, which was confirmed by the SPAD index. Tannery sludge provided the highest production of flavonoids. The comparison between the two forms of evaluation showed that the abaxial part of the leaf had greater sensitivity and that the Multiplex® sensor showed higher sensitivity for detection of indices. No changes were found in plant photosynthesis. However, greater stress was detected in the treatment with tannery sludge.
1 RESUMO Este trabalho teve por objetivo estudar a variação de vazão em tubogotejadores NaanPC laranja e NaanPC azul em função de precipitados químicos, ao longo do tempo de funcionamento, quando submetidos a uma água rica em ferro, avaliando-se especificamente o coeficiente de uniformidade de Christiansen (CUC) e o coeficiente de uniformidade de distribuição (CUD). O experimento foi desenvolvido em uma bancada de ensaios para tubogotejadores no Laboratório de Ensaio de Equipamentos para Irrigação do Departamento de Engenharia Rural da Faculdade de Ciências Agronômicas - UNESP, localizado no município de Botucatu – SP. O experimento foi montado em esquema fatorial 2x2x7, sendo duas doses de Fe, dois modelos de gotejadores e sete tempos de funcionamento, com três repetições, totalizando 84 parcelas experimentais. Efetuou-se a análise de variância pelo teste F. As médias das vazões dos gotejadores foram comparadas pelo teste de T de Student a 5% de probabilidade. Os resultados obtidos não apontaram diferença significativa nas diferentes doses de ferro. Entretanto, os resultados apontaram diferença significativa na interação gotejador x tempo e coeficiente de uniformidade de Christiansen (CUC). UNITERMOS: coeficiente de uniformidade de Christiansen(CUC), coeficiente de uniformidade de distribuição (CUD), entupimento de emissores. BRAUER, R.L; CRUZ, R. L; VILLAS BÔAS, R. L.; PLETSCH, T. A.EVALUATION OFWATER APPLICATION UNIFORMITY IN DRIPPERSIN FUNCTION OF IRON CONTENT 2 ABSTRACT This work aimed to study the occurrence of chemical precipitates effects in two types of drip hose (NaanPC orange and blue) due to chemical precipitation along the operating time, when subjected to water rich in iron, specifically evaluating the Christiansen uniformity coefficient (CUC) and distribution uniformity (DU). The experiment was conducted in a test bench for drip hose at Laboratory Test Equipment for Irrigation - Department of Agricultural Engineering, Sao Paulo State University. The experiment was a 2 x 2 x 7 factorial design, with two Fe doses, two drip brands, and seven operational times with three replicates, totalizing 84 experimental plots. The variance analysis was performed by F test. Average emitter discharges were compared by Student t test at 5% probability. The results showed no significant difference in iron doses. However, the results indicated significant differences in drip versus operational time and the Christiansen uniformity coefficient (CUC). KEYWORDS: Uniformity coefficient of Christiansen(CUC), distribution uniformity (DU), emitter clogging.
DESEMPENHO DE GOTEJADORES COM USO DE ESGOTO DOMÉSTICO TRATADO Talita Aparecida Pletsch1; Raimundo Leite Cruz1; Helton Rogério Mazzer2; Érika Fabiana de Oliveira11Departamento de Engenharia Rural, Faculdade de Ciências Agronômicas, Universidade estadual Paulista, Botucatu, SP, talita@fca.unesp.br2Departamento de Engenharia Civil, Universidade Federal Tecnológica Federal do Paraná, Campus de Campo Mourão, PR 1 RESUMO O presente trabalho teve como objetivo determinar a vazão dos gotejadores, a curva relação vazão-pressão, a sua equação característica, o coeficiente de variação de vazão (CVQ), e também avaliar a uniformidade de aplicação de água, do tubo gotejador da marca Netafim, modelo Tiran 17, utilizado para a irrigação com esgoto doméstico tratado. Após 1000 horas de uso do tubo gotejador, o entupimento de gotejadores reduziu a uniformidade de aplicação de água de 98% para valores menores que 60%, e aumentou o coeficiente de variação de vazão a valores maiores que 0,29. UNITERMOS: coeficiente de variação de fabricação, reúso de água PLETSCH, T. A.; CRUZ, R. L.; MAZZER, H. R.; OLIVEIRA, É. F. de. PERFORMANCE OF DRIPPERS USING TREATED DOMESTIC WASTEWATER 2 ABSTRACT This paper aimed to determine the flow rate of drippers, their “flow rate-pressure” curve, their equation, their flow rate variation coefficient (VCq), as well as to evaluate the uniformity of water application of the Netafim drip pipe,Tiran17 model, used for irrigation with domestic wastewater from treated household drain. After 1000 working hours, the blockage of some drippers decreased the uniformity of water application from 98% to lower than 60% and increased the flow variation coefficient to values higher than 0.29. KEYWORDS: flow rate variation coefficient, wastewater
Direitos para esta edição cedidos à Atena Editora pelos autores. Todo o conteúdo deste livro está licenciado sob uma Licença de Atribuição Creative Commons. Atribuição-Não-Comercial-NãoDerivativos 4.0 Internacional (CC BY-NC-ND 4.0).O conteúdo dos artigos e seus dados em sua forma, correção e confiabilidade são de responsabilidade exclusiva dos autores, inclusive não representam necessariamente a posição oficial da Atena Editora. Permitido o download da obra e o compartilhamento desde que sejam atribuídos créditos aos autores, mas sem a possibilidade de alterá-la de nenhuma forma ou utilizá-la para fins comerciais. Todos os manuscritos foram previamente submetidos à avaliação cega pelos pares, membros do Conselho Editorial desta Editora, tendo sido aprovados para a publicação com base em critérios de neutralidade e imparcialidade acadêmica.A Atena Editora é comprometida em garantir a integridade editorial em todas as etapas do processo de publicação, evitando plágio, dados ou resultados fraudulentos e impedindo que interesses financeiros comprometam os padrões éticos da publicação. Situações suspeitas de má conduta científica serão investigadas sob o mais alto padrão de rigor acadêmico e ético.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.