Fracture toughness testing in the elastic-plastic temperature range of material behavior is described in the Master Curve standard ASTM 1921-97. The standard allows measurement of valid fracture toughness values up to KJC= 100 MPa√m with clearly smaller than standard CVN-size specimens for the irradiated material condition. However, a relatively small amount of data measured with miniature specimens of cross-sections 5 mm × 5 mm or 3 mm × 4 mm have been published and hence the utilization of such small specimens is generally not accepted even if the universal specimen size criteria are fulfilled. In this study, the fracture toughness transition temperature T0 has been measured for a high phosphorus content WWER 440 weld coded as W502 both in the non-irradiated and in the irradiated and annealed material conditions. Three-point bend specimens of cross-sections 10 mm × 10 mm, 5 mm × 5 mm and 3 mm × 4mm were used in the study.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.