Wear of metallic surfaces after total knee arthroplasty is uncommon. In this case, we report a catastrophic failure of the knee prosthesis in a 60-year-old male patient who had undergone total knee prosthesis 7 years prior to his admission to our clinic. Genu recurvatum was observed in the affected knee. Surgical exploration of the knee showed wear of the polyethylene insert accompanied by metallic tibial component abrasion of the posterior-cruciate-retaining total knee prosthesis (Maxim, Biomet, Warsaw, IN, USA). Single-stage revision was performed, and a new total knee prosthesis was implanted (Legion, Smith & Nephew, Memphis, TN, USA). Postoperative examination showed improved stability and correction of recurvatum of the affected knee and follow-up examination showed improved weight bearing ability and better overall functional outcome.
Rupture of patellar tendon is one of the rarest injuries of childhood which require acute repair to preserve extensor mechanism. In this report, we present 12-year-old male patient, otherwise healthy who admitted with a rupture of patellar tendon without bony involvement. Treatment involved end-to-end suture, support with anchors and patellar reinforcement with a cerclage wire, combination of which was not documented earlier for the pediatric group in the prior literature. Early range of motion exercises started with functional knee brace. Final follow-up showed improved functional outcome.
Wear of metallic surfaces after total knee arthroplasty is uncommon. In this case, we report a catastrophic failure of the knee prosthesis in a 60-year-old male patient who had undergone total knee prosthesis 7 years prior to his admission to our clinic. Genu recurvatum was observed in the affected knee. Surgical exploration of the knee showed wear of the polyethylene insert accompanied by metallic tibial component abrasion of the posterior-cruciate-retaining total knee prosthesis (Maxim, Biomet, Warsaw, IN, USA). Single-stage revision was performed, and a new total knee prosthesis was implanted (Legion, Smith & Nephew, Memphis, TN, USA). Postoperative examination showed improved stability and correction of recurvatum of the affected knee and follow-up examination showed improved weight bearing ability and better overall functional outcome.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.