Most aortoiliac anatomic characteristics remained unchanged post-EVAS. Filling of the endobags to a pressure of 180 mmHg may lead to lost thrombus volume in some patients, probably because liquid is squeezed into lumbar or the inferior mesenteric artery. The absolute differences in pre- and post-EVAS aortoiliac lengths were small, so pre-operative sizing is accurate for determining stent length.
Background and purpose — Gait analysis performed under increased physical demand may detect differences in gait between total (THA) versus resurfacing hip arthroplasty (RHA), which are not measured at normal walking speed. We hypothesized that patients after RHA would reach higher walking speeds and inclines compared with THA. Additionally, an RHA would enable a more natural gait when comparing the operated with the healthy contralateral hip.
Patients and methods — From a randomized controlled trial comparing THA with RHA with at least 5 years’ follow-up patients with a UCLA score of more than 3 points (n = 34) were included for an instrumented treadmill gait analysis. 25 patients with a unilateral implant (primary analysis—16 THA versus 9 RHA) and 9 patients with a bilateral implant (sub-analysis—n = 5 RHA + THA; n = 4 THA + THA). Spatiotemporal parameters, ground reaction forces, and range of motion were recorded at increasing walking speeds and inclines. Functional outcome scores were obtained.
Results — At a normal walking speed of 1.1 m/s and at increasing inclines no differences were recorded in gait between the 2 groups with a unilateral hip implant. With increasing walking speed the RHA group reached a higher top walking speed (TWS) (adjusted difference 0.07 m/s, 95% CI –0.11 to 0.25) compared with THA. Additionally, RHA patients tolerated more weight on the operated side at TWS (155 N, CI 49–261) and as such weight-bearing approached the unaffected contralateral side. For the RHA group a “between leg difference” of 8 N (CI 3–245) was measured versus –129 N (CI –138 to –29) for THA (adjusted difference 144 N, CI 20–261). Hip flexion of the operated side at TWS was higher after RHA compared with THA (adjusted difference 8°, CI 1.7–14).
Interpretation — In this study RHA patients reached a higher walking speed, and preserved a more normal weight acceptance and a greater range of hip flexion against their contralateral healthy leg as compared with patients with a THA.
ObjectivesVarious configurations of kissing stent (KS) configurations exist and patency rates vary. In response the covered endovascular reconstruction of the aortic bifurcation configuration was designed to minimize mismatch and improve outcome. The aim of the current study is to compare geometrical mismatch of kissing stent with the covered endovascular reconstruction of the aortic bifurcation configuration in vivo.MethodsPost-operative computed tomographic data and patient demographics from 11 covered endovascular reconstruction of the aortic bifurcation and 11 matched kissing stent patients were included. A free hand region of interest and ellipse fitting method were applied to determine mismatch areas and volumes. Conformation of the stents to the vessel wall was expressed using the D-ratio.ResultsPatients were mostly treated for Rutherford category 2 and 3 (64%) with a lesion classification of TASC C and D in 82%. Radial mismatch area and volume for the covered endovascular reconstruction of the aortic bifurcation group was significantly lower compared to the kissing stent configuration (P < 0.05). The D-ratio did not significantly differ between groups. Measurements were performed with good intra-class correlation. There were no significant differences in the post-procedural aortoiliac anatomy.ConclusionsThe present study shows that radial mismatch exists in vivo and that large differences in mismatch exist, in favour of the covered endovascular reconstruction of the aortic bifurcation configuration. Future research should determine if the decreased radial mismatch results in improved local flow profiles and subsequent clinical outcome.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.