To study the potential usefulness of technetium-99m hexakis-2-methoxy-2-methylpropyl-isonitrile (Tc-MIBI) as a cardiac perfusion imaging agent, the left circumflex coronary arteries of 12 dogs were partially occluded. Eight additional control dogs had no coronary artery stenosis. Myocardial Tc-MIBI activities in the left circumflex and left anterior descending zones were continuously monitored by miniature implantable radiation detectors for 4 hr after administration of the isotope. The dogs were then killed. Serial gamma camera images were also acquired during the study. Heart rate, arterial blood pressure, pressure distal to the stenosis, and cardiac output did not change significantly during the experiment. Microsphere-determined regional myocardial blood flow was significantly reduced in the left circumflex distribution in the 12 dogs with coronary artery stenoses. In the 12 dogs with left circumflex coronary artery stenoses, the 4 hr fractional Tc-MIBI clearances from the normal and ischemic zones were minimal and equivalent (0.15 + 0.05 SD vs 0.15 ± 0.07). In the eight control dogs, 4 hr fractional Tc-MIBI clearances from the left anterior descending and left circumflex artery zones were minimal and equivalent (0.11 ± 0.06 vs 0.10 + 0.07). Four hour fractional Tc-MIBI clearance from the blood was 0.98 ± 0.03 for the dogs with stenosis and 0.97 + 0.02 for the dogs without stenosis. One additional dog had complete occlusion of the left circumflex coronary artery followed by administration of Tc-MIBI and scandium-46-labeled microspheres. This heart was immediately sectioned and counted to determine the relationship of regional blood flow to Tc-MIBI distribution (r = .92). Furthermore, the final technetium activity ratio (ischemic divided by normal zone = 0.53 + 0.19) measured in a well counter for the 12 dogs with stenosis was not significantly different from the initial flow ratio at the time of Tc-MIBI administration (0.47 ± 0.20), confirming the absence of redistribution. Gamma camera images were of excellent quality for as l-ong as 4 hr after isotope administration. Thus its linear relationship to regional myocardial blood flow, the minimal myocardial washout and redistribution, and the 140 keV gamma photon make Tc-MIBI a promising new cardiac perfusion imaging agent. Circulation 77, No. 2, 491-498, 1988. THALLIUM -201 has been widely used for the assessment of myocardial perfusion and the diagnosis of coronary artery disease. Unfortunately, its physical properties are not ideal for gamma camera imaging,' and myocardial image quality has sometimes suffered from external or self attenuation. This has resulted in considerable interobserver variability in interpretation of thallium images. Technetium-99m (99mTc) is much better suited for gamma camera imaging because of its 140 keV gamma photon. Previous attempts to link
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.