Purpose
The measurement of standard visual acuity (VA) is the most well‐known part of any ophthalmic examination to indicate visual function. Despite this, it is insensitive in detecting early disease changes. Therefore, other visual function tests have been developed including low luminance VA (LLVA) and low luminance deficit (LLD). This scoping literature review aims to summarise the current published applications of LLVA and LLD assessments to evaluate their utility as clinical markers and research outcome measures in a variety of ophthalmic conditions.
Recent findings
Sixty‐five peer‐reviewed publications were included. LLVA was pioneered for use in geographic atrophy, a subtype of age‐related macular degeneration, which remains the mainstay of its clinical application. However, other studies have reported additional useful applications in inherited retinal diseases including rare maculopathies and rod‐cone dystrophies. Although there are some variations in testing methodology, use of the standard Early Treatment Diabetic Retinopathy Study (ETDRS) chart with a 2.0 log unit neutral density filter is the most popular approach. The optimal testing luminance is still to be defined.
Summary
Overall, LLVA is an earlier clinical marker of change in central retinal function than standard VA. It has been shown to be a risk factor for disease progression and a better indicator of a patient’s level of everyday visual function. It is inexpensive and simple to implement using readily available standard ophthalmic equipment.
Purpose
Mean retinal sensitivity is the main output measure used in microperimetry. It is, however, of limited use in patients with poor vision because averaging is weighted toward zero in those with significant scotomas creating an artificial floor effect. In contrast, volumetric measures avoid these issues and are displayed graphically as a hill of vision.
Methods
An open-source program was created to manipulate raw sensitivity threshold data files obtained from MAIA microperimetry. Thin plate spline interpolated heat maps and three-dimensional hill of vision plots with an associated volume were generated. Retrospective analyses of microperimetry volumes were undertaken in patients with a range of retinal diseases to assess the qualitative benefits of three-dimensional visualization and volumetric measures. Simulated pathology was applied to radial grid patterns to investigate the performance of volumetric sensitivity in nonuniform grids.
Results
Volumetric analyses from microperimetry in
RPGR
-related retinitis pigmentosa, choroideremia, Stargardt disease, and age-related macular degeneration were analyzed. In simulated nonuniform testing grids, volumetric sensitivity was able to detect differences in retinal sensitivity where mean sensitivity could not.
Conclusions
Volumetric measures do not suffer from averaging issues and demonstrate superior performance in nonuniform testing grids. Additionally, volume measures enable detection of localized retinal sensitivity changes that might otherwise be undetectable in a mean change.
Translational Relevance
As microperimetry has become an outcome measure in several gene-therapy clinical trials, three-dimensional visualization and volumetric sensitivity enables a complementary analysis of baseline disease characteristics and subsequent response to treatment, both as a signal of safety and efficacy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.