Background: Three-dimensional (3D) multiecho balanced steady-state free precession (ME-bSSFP) has previously been demonstrated in preclinical hyperpolarized (HP) 13 C-MRI in vivo experiments, and it may be suitable for clinical metabolic imaging of prostate cancer (PCa). Purpose: To validate a signal simulation framework for the use of sequence parameter optimization. To demonstrate the feasibility of ME-bSSFP for HP 13 C-MRI in patients. To evaluate the metabolism in PCa measured by ME-bSSFP. Study Type: Retrospective single-center cohort study.
Background and Aims
The simplified magnetic resonance enterography (MRE) index (sMARIA), London and “extended” London scoring systems are widely used in Crohn’s disease (CD) to assess disease activity, although validation studies have usually been single centre, retrospective and/or used few readers. Here, we evaluated these MRE indices within a prospective multicentre, multireader diagnostic accuracy trial.
Methods
A subset of participants (newly diagnosed or suspected of relapse) recruited to the METRIC trial with available terminal ileal (TI) biopsies was included. Using pre-specified thresholds, the sensitivity and specificity of sMARIA, London and “extended” London scores for active and severe (sMARIA) TI CD were calculated using different thresholds for the histological activity index (HAI).
Results
We studied 111 patients (median 29 years, interquartile range 21-41, 75 newly diagnosed, 36 suspected relapse) from 7 centres, of whom 22 had no active TI CD (HAI=0), 39 mild (HAI=1), 13 moderate (HAI=2), and 37 severe CD activity (HAI=3). In total, 26 radiologists prospectively scored MRE datasets as per their usual clinical practice. Sensitivity and specificity for active disease (HAI>0) were 83% (95% confidence interval 74-90%) and 41% (23-61%) for sMARIA, 76% (67-84%) and 64% (43-80%) for the London score, and 81% (72-88%) and 41% (23-61%) for the “extended” London score, respectively. The sMARIA had 84% (69-92%) sensitivity and 53% (41-64%) specificity for severe CD.
Conclusions
When tested at their proposed cut-offs in a real-world setting, sMARIA, London and “extended” London indices achieve high sensitivity for active TI disease against a histological reference standard, but specificity is low.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.