The yeast strains Cryptococcus podzolicus, Trichosporon porosum and Pichia segobiensis were isolated from soil samples and identified as oleaginous yeast strains beneficial for the establishment of microbial production processes for sustainable lipid production suitable for several industrial applications. When cultured in bioreactors with glucose as the sole carbon source C. podzolicus yielded 31.8% lipid per dry biomass at 20°C, while T. porosum yielded 34.1% at 25°C and P. segobiensis 24.6% at 25°C. These amounts correspond to lipid concentrations of 17.97 g/L, 17.02 g/L and 12.7 g/L and volumetric productivities of 0.09 g/Lh, 0.1 g/Lh and 0.07 g/Lh, respectively. During the culture of C. podzolicus 30 g/l gluconic acid was detected as by-product in the culture broth and 12 g/L gluconic acid in T. porosum culture. The production of gluconic acid was eliminated for both strains when glucose was substituted by xylose as the carbon source. Using xylose lipid yields were 11.1 g/L and 13.9 g/L, corresponding to 26.8% and 33.4% lipid per dry biomass and a volumetric productivity of 0.07 g/Lh and 0.09 g/Lh, for C. podzolicus and T. porosum respectively. The fatty acid profile analysis showed that oleic acid was the main component (39.6 to 59.4%) in all three strains and could be applicable for biodiesel production. Palmitic acid (18.4 to 21.1%) and linolenic acid (7.5 to 18.7%) are valuable for cosmetic applications. P. segobiensis had a considerable amount of palmitoleic acid (16% content) and may be suitable for medical applications.
Oil is a prominent, but multifaceted material class with a wide variety of applications. Technical oils, crude oils as well as edibles are main subclasses. In this review, the question is addressed how low-field NMR can contribute in oil characterization as an analytical tool, mainly with respect to quality control. Prerequisite in the development of a quality control application, however, is a detailed understanding of the oils and of the measurement. Low-field NMR is known as a rich methodical toolbox that was and is explored and further developed to address questions about oils, their quality, and usability as raw materials, during production and formulation as well as in use.
Process monitoring and control require dedicated and reliable measures which reflect the status of the process under investigation. Although nuclear magnetic resonanceis known to be a versatile analytical technique, it is only seldomly found in process monitoring. Single-sided nuclear magnetic resonance is one well known approach for being applied in process monitoring. The dedicated V-sensor is a recent approach that allows the inline investigation of materials in a pipe non-destructively and non-invasively. An open geometry of the radiofrequency unit is realized using a tailored coil, enabling the sensor to be applied for manifold mobile applications in in-line process monitoring. Stationary liquids were measured, and their properties were integrally quantified as the basis for successful process monitoring. The sensor, in its inline version, is presented along with its characteristics. An exemplary field of application is battery production in terms of anode slurries; thus, the first results on graphite slurries will demonstrate the added value of the sensor in process monitoring.
The current trend for ultra-high-field magnetic resonance imaging (MRI) technologies opens up new routes in clinical diagnostic imaging as well as in material imaging applications. MRI selectivity is further improved by using contrast agents (CAs), which enhance the image contrast and improve specificity by the paramagnetic relaxation enhancement (PRE) mechanism. Generally, the efficacy of a CA at a given magnetic field is measured by its longitudinal and transverse relaxivities r1 and r2, i.e., the longitudinal and transverse relaxation rates T1−1 and T2−1 normalized to CA concentration. However, even though basic NMR sensitivity and resolution become better in stronger fields, r1 of classic CA generally decreases, which often causes a reduction of the image contrast. In this regard, there is a growing interest in the development of new contrast agents that would be suitable to work at higher magnetic fields. One of the strategies to increase imaging contrast at high magnetic field is to inspect other paramagnetic ions than the commonly used Gd(III)-based CAs. For lanthanides, the magnetic moment can be higher than that of the isotropic Gd(III) ion. In addition, the symmetry of electronic ground state influences the PRE properties of a compound apart from diverse correlation times. In this work, PRE of water 1H has been investigated over a wide range of magnetic fields for aqueous solutions of the lanthanide containing polyoxometalates [DyIII(H2O)4GeW11O39]5– (Dy-W11), [ErIII(H2O)3GeW11O39]5– (Er-W11) and [{ErIII(H2O)(CH3COO)(P2W17O61)}2]16− (Er2-W34) over a wide range of frequencies from 20 MHz to 1.4 GHz. Their relaxivities r1 and r2 increase with increasing applied fields. These results indicate that the three chosen POM systems are potential candidates for contrast agents, especially at high magnetic fields.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.