Cochrane Database of Systematic Reviews
Data collection and analysisTwo review authors independently collected the data from each study and evaluated methodological quality according to the Quality Assessment of Studies of Diagnostic Accuracy -Revised (QUADAS-2) tool. We used the bivariate random-e ects model to obtain summary estimates of sensitivity and specificity.
Main resultsWe identified 64 studies including 71 separate study populations with a total of 10,280 participants (4583 with and 5697 without acute appendicitis). Estimates of sensitivity ranged from 0.72 to 1.0 and estimates of specificity ranged from 0.5 to 1.0 across the 71 study populations. Summary sensitivity was 0.95 (95% confidence interval (CI) 0.93 to 0.96), and summary specificity was 0.94 (95% CI 0.92 to 0.95). At the median prevalence of appendicitis (0.43), the probability of having appendicitis following a positive CT result was 0.92 (95% CI 0.90 to 0.94), and the probability of having appendicitis following a negative CT result was 0.04 (95% CI 0.03 to 0.05). In subgroup analyses according to contrast enhancement, summary sensitivity was higher for CT with intravenous contrast (0.96, 95% CI 0.92 to 0.98), CT with rectal contrast (0.97, 95% CI 0.93 to 0.99), and CT with intravenous and oral contrast enhancement (0.96, 95% CI 0.93 to 0.98) than for unenhanced CT (0.91, 95% CI 0.87 to 0.93). Summary sensitivity of CT with oral contrast enhancement (0.89, 95% CI 0.81 to 0.94) and unenhanced CT was similar. Results show practically no di erences in summary specificity, which varied from 0.93 (95% CI 0.90 to 0.95) to 0.95 (95% CI 0.90 to 0.98) between subgroups. Summary sensitivity for low-dose CT (0.94, 95% 0.90 to 0.97) was similar to summary sensitivity for standard-dose or unspecified-dose CT (0.95, 95% 0.93 to 0.96); summary specificity did not di er between lowdose and standard-dose or unspecified-dose CT. No studies had high methodological quality as evaluated by the QUADAS-2 tool. Major methodological problems were poor reference standards and partial verification primarily due to inadequate and incomplete follow-up in persons who did not have surgery.
Authors' conclusionsThe sensitivity and specificity of CT for diagnosing appendicitis in adults are high. Unenhanced standard-dose CT appears to have lower sensitivity than standard-dose CT with intravenous, rectal, or oral and intravenous contrast enhancement. Use of di erent types of contrast enhancement or no enhancement does not appear to a ect specificity. Di erences in sensitivity and specificity between low-dose and standard-dose CT appear to be negligible. The results of this review should be interpreted with caution for two reasons. First, these results are based on studies of low methodological quality. Second, the comparisons between types of contrast enhancement and radiation dose may be unreliable because they are based on indirect comparisons that may be confounded by other factors.How reliable are the results of the studies in this review? Among the included studies, th...
The combined regimen of mifepristone and misoprostol is effective in the second trimester, and the interval between the drugs can be reduced allowing individualised patient care.
Single dose misoprostol reduced the number of surgical interventions. The success rates of medically-treated first trimester miscarriages varied according to the ultrasonographic definitions of pregnancy failure, time of assessment, and the criteria for success.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.