This is a retrospective study to evaluate the prevention of complications of metallic stent placement in patients with unresectable advanced esophageal cancer. A total of 87 patients were treated with 4 types of metal stents in the esophagus over a period of 18 years. Stent placement was technically successful. The most common prior treatment was chemoradiotherapy. There were no significant differences in the rate of patients with no complications among the prior treatments. Approximately, 30% of patients had the most common chest pain in complications. Stent placement within one month after the completion of chemoradiotherapy should be avoided for the prevention of the chest pain. There was no significant difference in the rate of patients with no complications by lesion location. The rate of no complications was higher for the Niti-S stent than the Gianturco Z-stent or Ultraflex stent. Of note, no complications were noted for the Niti-S ultrathin stent at all. Among cases of stent-related death, the most common type of complication was respiratory disorder caused by the stent that seems to be thick and hard. Therefore, the stent with thin and flexible characteristics like the Niti-S ultrathin stent will solve the various problems of esophageal stent placement.
Schwannomas are tumors and commonly occur in the head and neck region; however, they rarely present in the retroperitoneum. A 79-year-old man was admitted to our hospital for a follow-up of a tumor in the hepatic hilus. A 2.8 × 2.5 cm solid tumor located between the hepatic hilus and common hepatic artery was originally identified, and the size of the tumor had increased from 2.0 × 2.0 cm to 2.8 × 2.5 cm over the course of 3 years. The patient underwent percutaneous sonopsy, and the tumor was subsequently diagnosed as a benign schwannoma. Since the patient wished to undergo an operation, we performed laparoscopic surgery. During the operation, the tumor was detected in the retroperitoneal space, where it was strongly adhered between the left gastric artery and common hepatic artery. At this point, no major vessels had vascularized the tumor. We then completely removed the tumor from the retroperitoneal space without any complications. The clinical course was uneventful, and the patient was discharged on postoperative day 4 without any symptoms. Later, a definitive histopathologic examination revealed a benign schwannoma. Here, we report this rare case of a retroperitoneal schwannoma located in the hepatic hilus.
Background and aimsEUS-guided FNA biopsy has been widely performed to aid in the diagnosis of submucosal tumors (SMTs). However, in cases of small tumors, the diagnostic yield of EUS-FNA is poor. Therefore, it is necessary to develop a new needle for the diagnosis. We developed a device with a new mechanism that we refer to as a drill needle aspiration biopsy (DNAB). The aim of this study was to evaluate the use of DNAB in resected gastric SMT specimens.MethodsA drill needle with a sharp tip and wide ditch was inserted into a catheter for angiography. Continuous suction is enabled through the catheter at the tip. DNAB was performed with one pass and one stroke in 13 gastric SMTs resected by operation. Similarly, FNA was performed by one pass and ten strokes. These gastric tumors included nine diagnosed gastrointestinal stromal tumors and four undiagnosed SMTs by preoperative examinations. The tissue quantity between DNAB and FNA was macroscopically and microscopically examined.ResultsAll 13 drill biopsy specimens were obtained. Additionally, all 13 gastric SMTs, including 4 undiagnosed tumors, could be diagnosed by DNAB. The quantity of each specimen obtained by DNAB was macroscopically and microscopically much greater than that by FNA. In particular, for tumors <25 mm in the longer axis, the ratio of microscopic diagnosable cases was 100 % (7/7) for DNAB and 42.9 % (3/7) for FNA.ConclusionsDNAB is a novel method that can obtain more tissue than FNA for small gastric SMT.
A 65-year-old man with cT1bN0M0 stage I middle thoracic esophageal cancer underwent subtotal esophagectomy and gastric tube reconstruction through the posterior mediastinal route after preoperative carbon-ion radiotherapy and chemotherapy in a clinical trial. Anastomotic leakage occurred, but it spontaneously improved. At six months after the operation, he was rehospitalized with a cough and dysphagia. An esophago-bronchiole fistula and stenosis of the gastric tube were observed. He first underwent stent placement in the gastric tube. Two weeks later, the syringeal epithelium was burned by argon plasma coagulation after stent removal. Endoscopic occlusion was then performed for the fistula with two guidewire-assisted silicone spigots. Two weeks later, he was discharged on an oral diet, and he has not developed recurrence of the fistula or cancer for three years. This is the first report of endoscopic occlusion with a guidewire-assisted silicone spigot through the esophagus.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.