SummaryRecent studies have shown that potentially hazardous volatile organic compounds (VOCs) and ultrafine particles (UFPs) are emitted from many desktop three-dimensional printer and filament combinations. We use recently published measurements of UFP and speciated VOC emission rates from a number of desktop 3D printers and filaments to predict the magnitudes of human exposures to airborne pollutants that would be expected in multiple locations within a typical small office environment. We also model the impacts of several control strategies for reducing occupational exposures. Results demonstrate that UFP and VOC concentrations within close or moderate proximity (i.e., within 3 and 3 to 18 meters, respectively) to some desktop 3D printer and filament combinations with the highest emissions can exceed recommended exposure levels (RELs) for some VOCs and typical indoor concentrations for both UFPs and VOCs. Concentrations of caprolactam within close proximity to a printer using some nylon-based filaments are predicted to exceed both acute and chronic RELs set by the California Office of Environmental Health Hazard Assessment. UFP concentrations are predicted to reach as high as 80,000 particles per cubic centimeter in close proximity to the highest emitting printer and filament combinations. The printer and filament combinations with the lowest UFP and VOC emission rates are not expected to yield concentrations at levels of concern. The most effective control strategies for reducing both UFP and VOC concentrations included installing a high-flow spot ventilation system and operating the printer in a sealed enclosure with high-efficiency gas and particle filtration.
Particle air filters used in central residential forced‐air systems are most commonly evaluated for their size‐resolved removal efficiency for particles 0.3‐10 µm using laboratory tests. Little information exists on the removal efficiency of commercially available residential filters for particles smaller than 0.3 µm or for integral measures of mass‐based aerosol concentrations (eg, PM2.5) or total number concentrations (eg, ultrafine particles, or UFPs) that are commonly used in regulatory monitoring and building measurements. Here, we measure the size‐resolved removal efficiency of 50 new commercially available residential HVAC filters installed in a recirculating central air‐handling unit in an unoccupied apartment unit using alternating upstream/downstream measurements with incense and NaCl as particle sources. Size‐resolved removal efficiencies are then used to estimate integral measures of PM2.5 and total UFP removal efficiency for the filters assuming they are challenged by 201 residential indoor particle size distributions (PSDs) gathered from the literature. Total UFP and PM2.5 removal efficiencies generally increased with manufacturer‐reported filter ratings and with filter thickness, albeit with numerous exceptions. PM2.5 removal efficiencies were more influenced by the assumption for indoor PSD than total UFP removal efficiencies. Filters with the same ratings but from different manufacturers often had different removal efficiencies for PM2.5 and total UFPs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.