Yttrium tetragonal zirconia polycrystal frameworks were prepared for all-ceramic fixed partial dentures (FPDs) for the mandibular incisor region. The effects of the cross-sectional area and morphology of the connector on its strength were evaluated by fracture tests. Nine types of zirconia framework for a 3-unit FPD for a defect of 1 mandibular central incisor were prepared, each differing in cross-sectional area and morphology. Fracture tests were performed by loading until fracture using a universal testing machine. Fracture load was determined and fracture site examined. Significant differences were observed in fracture load according to the morphology and crosssectional area of the connector (p<0.05, p<0.01, p<0.001). Fracture load differed significantly among all groups according to cross-sectional area, and was also greater when the shape of the connector formed an isosceles triangle widest at the base and the connector had the same height and width. These values still far exceeded 311 N, however, which is the average occlusal force in the incisor region. The results of this study suggest that connector design affects fracture load.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations鈥揷itations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.