B-RTO is an effective method for gastric varices with gastrorenal shunt and provides lower recurrence and bleeding rates. We believe that B-RTO can become a standard treatment for gastric varices with gastrorenal shunt, although treatment of worsened esophageal varices may be necessary after B-RTO.
Purpose: To clarify the diagnostic accuracy of diffusionweighted imaging (DWI) in differentiating benign from malignant ovarian lesions.
Materials and Methods:We retrospectively analyzed magnetic resonance images of 123 ovarian lesions in 119 patients. We defined lesions with abnormal signal intensity as malignancy and assessed the location of abnormal intensity within the lesions on DWI. We also assessed the mean and lowest apparent diffusion coefficient (ADC) values of the solid portion for each ovarian lesion.
Results:The majority of malignant ovarian tumors and mature cystic teratomas, and almost half of the endometriomas, showed abnormal signal intensity on DWI, whereas most fibromas and other benign lesions did not. The main locations of abnormal signal intensity were solid portions in malignant ovarian tumors, cystic components suggestive of keratinoid substances and Rokitansky protuberance in mature cystic teratomas, and intracystic clots in endometriomas. On DW imaging, receiver-operating characteristic analysis yielded mean Az values of 0.703. There was no significant difference in mean and lowest ADC values between malignant and benign lesions.Conclusion: DWI of ovarian lesions and ADC values of the solid component are not useful for differentiating benign from malignant ovarian lesions. This knowledge is essential in avoiding misinterpretation in the diagnosis of ovarian lesions.
Our purpose is to evaluate the diagnostic accuracy of apparent diffusion coefficient (ADC) measurement in differentiating malignant from benign uterine endometrial cavity lesions. We retrospectively evaluated 25 uterine endometrial cavity lesions in 25 female patients: endometrial carcinoma (n = 11), carcinosarcoma (n = 2), submucosal leiomyoma (n = 8), and endometrial polyp (n = 4). Diffusion-weighted images were performed at 1.5 T with b factors of 0-1,000/mm(2). The region of interest was defined within the tumor on T2-weighted EPI image and then manually copied to an ADC map. Thereby, the ADC value was obtained. We compared ADC values between malignant and benign lesions using Student's t-test. The mean and standard deviation of ADC values (x10(-3) mm(2)/s) were as follows: endometrial carcinoma, 0.98+/-0.21; carcinosarcoma, 0.97+/-0.02; submucosal leiomyoma, 1.37+/-0.28; and endometrial polyp, 1.58+/-0.45. The ADC values differed significantly between malignant (0.98+/-0.19) and benign lesions (1.44+/-0.34) (P < 0.01). We defined malignant tumors as cases with an ADC value less than 1.15 x 10(-3) mm(2)/s for obtaining the highest accuracy. Sensitivity, specificity, and accuracy were 84.6%, 100%, and 92%, respectively. ADC measurement can provide useful information in differentiating malignant from benign uterine endometrial cavity lesions.
Based on the direct correlation between postportem NmMRI and neuropathological findings, signal intensity in the SNc is closely related to the quantity of neuromelanin-containing neurons but is not influenced by iron deposition.
Evaluation of rADC values in characteristic lesions in MSA, PSP, and PD by placing ROIs using 3-T systems can provide useful additional information for differentiating these disorders.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.