Serum glucose and plasma C-peptide response t o IV glucagon administration was evaluated in 24 healthy dogs, 12 dogs with untreated diabetes mellitus, 30 dogs with insulintreated diabetes mellitus, and 8 dogs with naturally acquired hyperadrenocorticism. Serum insulin response also was evaluated in all dogs, except 20 insulin-treated diabetic dogs. Blood samples for serum glucose, serum insulin, and plasma C-peptide determinations were collected immediately before and 5,lO. 20,30, and (for healthy dogs) 60 minutes after IV administration of 1 mg glucagon per dog. In healthy dogs, the patterns of glucagon-stimulated changes in plasma Cpeptide and serum insulin concentrations were identical, with single peaks in plasma C-peptide and serum insulin concentrations observed approximately 15 minutes after IV glucagon administration. Mean plasma C-peptide and serum insulin concentrations in untreated diabetic dogs, and mean plasma C-peptide concentration in insulin-treated diabetic dogs did not increase significantly after IV glucagon administration. The validity of serum insulin concentration results was questionable in 10 insulin-treated diabetic dogs, possibly because of anti-insulin antibody interference with the insulin radioimmunoassay. Plasma C-peptide and serum insulin concentrations were significantly increased ( P < ,001) at all blood sarnplkg times after glucagon administration in dogs with hyperadrenocorticism, compared with healthy dogs, and untreated and insulin-treated diabetic dogs. Fiveminute C-peptide increment, C-peptide peak response, total C-peptide secretion, and, for untreated diabetic dogs, insulin he classification of diabetes mellitus into insulin-depen-T dent (IDDM), non-insulin -dependent (NIDDM), gestational, and subclinical diabetes with impaired glucose tolerance is dependent, in part, on results of insulin secretagogue testing." An IV glucagon tolerance test, with blood samples obtained for measurement of plasma insulin-connecting peptide (C-peptide) concentration prior to and 6 minutes after glucagon administration, is a widely used test of pancreatic &cell function in human^.^ C-peptide is a linear amino acid chain that "connects" the A and B chains of insulin within the proinsulin molecule. Proteolytic cleavage of pro- peak response and total insulin secretion were significantly lower ( P < .001) in diabetic dogs, compared with healthy dogs, whereas these same parameters were significantly increased ( P < ,011 in dogs with hyperadrenocorticism, compared with healthy dogs, and untreated and insulin-treated diabetic dogs. Although not statistically significant, there was a trend for higher plasma C-peptide concentrations in untreated diabetic dogs compared with insulin-treated diabetic dogs during the glucagon stimulation test. Baseline Cpeptide concentrations also were significantly higher ( P < .05) in diabetic dogs treated with insulin for less than 6 months, compared with diabetic dogs treated for longer than 1 year. Finally, 7 of 42 diabetic dogs had baseline plasma C-peptide concen...
Measurement of serum-free thyroxine (fT4) concentration provides a more accurate assessment of thyroid gland function than serum thyroxine (T4) or 3,5,3'-triiodothyronine (T3). Techniques for measuring serum fT4 concentration include standard equilibrium dialysis (SED), radioimmunoassay (RIA), and a combination of both (modified equilibrium dialysis [MED]). This study compared results of serum fT4 measurements by means of SED, MED, and 5 RIAs in 30 healthy dogs, 10 dogs with hypothyroidism, and 31 euthyroid dogs with concurrent illness for which hypothyroidism was a diagnostic consideration. Serum fT4 concentrations were comparable when determined by the SED and MED techniques, and mean serum fT4 concentrations were significantly (P < .01) lower in dogs with hypothyroidism than in healthy dogs and euthyroid dogs with concurrent illness. Significant (P < .05) differences in fT4 concentrations were identified among the 5 RIAs and among the RIAs and MED and SED. Serum fT4 concentrations were consistently lower when fT4 was determined by the RIAs, compared with either equilibrium dialysis technique. Serum fT4 concentrations were significantly lower (P < .01) in dogs with hypothyroidism than in healthy dogs for all RIAs; were significantly lower (P < .05) in dogs with hypothyroidism than in euthyroid dogs with concurrent illness for 4 RIAs; and were significantly lower (P < .01) in euthyroid dogs with concurrent illness than in healthy dogs for 4 RIAs. RIAs had the highest number of low serum fT4 concentrations in euthyroid dogs with concurrent illness. This study documented differences in test results among fT4 assays, emphasizing the importance of maintaining consistency in the assay used to measure serum fT4 concentrations in the clinical or research setting.
Measurement of serum-free thyroxine (fT4) concentration provides a more accurate assessment of thyroid gland function than serum thyroxine (T4) or 3,5,3'-triiodothyronine (T3). Techniques for measuring serum fT4 concentration include standard equilibrium dialysis (SED), radioimmunoassay (RIA), and a combination of both (modified equilibrium dialysis [MED]). This study compared results of serum fT4 measurements by means of SED, MED, and 5 RIAs in 30 healthy dogs, 10 dogs with hypothyroidism, and 31 euthyroid dogs with concurrent illness for which hypothyroidism was a diagnostic consideration. Serum fT4 concentrations were comparable when determined by the SED and MED techniques, and mean serum fT4 concentrations were significantly (P < .01) lower in dogs with hypothyroidism than in healthy dogs and euthyroid dogs with concurrent illness. Significant (P < .05) differences in fT4 concentrations were identified among the 5 RIAs and among the RIAs and MED and SED. Serum fT4 concentrations were consistently lower when fT4 was determined by the RIAs, compared with either equilibrium dialysis technique. Serum fT4 concentrations were significantly lower (P < .01) in dogs with hypothyroidism than in healthy dogs for all RIAs; were significantly lower (P < .05) in dogs with hypothyroidism than in euthyroid dogs with concurrent illness for 4 RIAs; and were significantly lower (P < .01) in euthyroid dogs with concurrent illness than in healthy dogs for 4 RIAs. RIAs had the highest number of low serum fT4 concentrations in euthyroid dogs with concurrent illness. This study documented differences in test results among fT4 assays, emphasizing the importance of maintaining consistency in the assay used to measure serum fT4 concentrations in the clinical or research setting.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.