A new differential pulse polarographic (DPP) method has been developed for the trace determination of boron. Its most stable copper complex is used in 0.5 M KNO 3 electrolyte since boron is not electroactive. By continuous addition of tetraborate to copper solution, the copper peak decreased first but then the peak became very small and nearly constant. This point was used for the boron determination. It was found that one mole of copper used two moles of tetraborate. Using this relationship, 1 Â 10 À5 M tetraborate could be determined. The quantification limit was 2.5 Â 10 À6 M and detection limit was 8 Â 10 À7 M. In the presence of complex forming ions such as Pb, Zn, and Cd, the borate found in sample was somewhat smaller because of their reaction with borate. But since their complexes were not as strong as copper, only a few percent of borate were used. No interference was observed in the presence of calcium, chloride and sulfate. This method is applied for the determination of B in borax ore, waste water of borax industries and tap water of Ankara city.
Vitamin B12 is a type of vitamin also known by the name cobalamin. B12 is involved in many metabolism activities, including DNA synthesis, nervous system, red blood formation and immune system. Therefore, we chose the Differential Pulse Polarography (DPP) method is that has a high sensitivity for the determination of vitamin B12. This determination was possible with cobalt present in vitamin B12 structure. Since Co(III) is formed from the oxidation of the vitamin, its polarographic behavior had to be determined in various electrolytes such as acetate, borate, phosphate and ammonia. The polarograms of Co(III) were taken in these electrolytes in which 1.0 M NH 3 /NH + 4 (pH = 9.8) and 1.0 M AcOH/AcO − (pH = 4.0) were found as the most suitable electrolytes. This method was successfully applied vitamin of B12 determination in a 1 mL ampoule with high precision. The LOD was found as 3.7 × 10 −7 for instead of (S/N = 3). Besides Co(III), interference effects of Zn(II), Ni(II), Cr(III), Fe(III), Cu(II), Cd(II) and Se(IV) were also studied. It was found that only Zn(II) peak had an overlap Co(III) peak in ammonium buffer. This problem could be solved by working in 1.0 M AcOH/AcO − (pH = 4.0) buffer. B12, which is 1000 µg in 1 mL vitamin ampoule, was found for 4 measurements as 999 ± 15 µg as a result of 95% confidence interval.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.