Study has been undertaken of the thermoluminescence (TL) yield of various tailor-made flat cross-section 6 mol% Ge-doped silica fibers, differing only in respect of external dimensions. Key TL dosimetric characteristics have been investigated, including glow curves, dose response, sensitivity, fading and reproducibility. Using a 60Co source, the samples were irradiated to doses within the range 1 to 10 Gy. Prior to irradiation, the flat fibers were sectioned into 6 mm lengths, weighed, and annealed at 400 °C for 1 h. TL readout was by means of a Harshaw Model 3500 TLD reader, with TLD-100 chips (LiF:Mg, Ti) used as a reference dosimeter to allow the relative response of the fibers to be evaluated. The fibers have been found to provide highly linear dose response and excellent reproducibility over the range of doses investigated, demonstrating high potential as TL-mode detectors in radiation medicine applications. Mass for mass, the results show the greatest TL yield to be provided by fibers of the smallest cross-section, analysis indicating this to be due to minimal light loss in transport of the TL through the bulk of the silica medium.
Dramatic improvements in radiotherapy equipment have allowed radiation fields to be conformed to tumours for more accurate treatment. Successful delivery often requires imaging at every treatment fraction, a method known as image guided radiation therapy (IGRT). But increased x-ray imaging exposes patients to doses that carry risks of inducing second cancers in normal tissues. Therefore, reductions in high-dose treatment margins achieved with IGRT must be balanced against detriments from greater imaging doses. ICRP Task Group 116 has been set up to prepare guidance on radiological protection aspects of IGRT. Factors affecting the optimization of radiological protection are the modalities used, the frequency of imaging, the image acquisition parameters influencing image quality and radiation dose, and the volume of normal tissue included in the images. The Task Group has undertaken two projects: (1) a snapshot survey of radiotherapy imaging practices across six continents, which has shown that use of kV cone beam CT (CBCT) increases with Human Development Index for the country; and (2) a project looking at ways for measuring CBCT doses that could be applied more widely. The results highlight the need for raising awareness of imaging doses, and development of the dose quantities displayed on imaging equipment used in radiotherapy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.