The purpose of this study was to find out if the use of 1.25-mm collimated thin-slice technique helps to detect more small pulmonary lung nodules than the use of 5 mm. A total of 100 patient examinations that allowed a reconstruction of 1.25-mm slice thickness in addition to the standard of 5-mm slices were included in a prospective study. Acquisition technique included four rows of 1-mm slices. Two sets of contiguous images were reconstructed and compared with 1.25- and 5-mm slice thickness, respectively. Two radiologists performed a film-based analysis of the images. The size and the confidence of the seen nodules were reported. We did not perform a histological verification, according to the normal clinical procedure, although it would be optimal regarding research. Statistical analysis was performed by using longitudinal analysis described by Brunner and Langer. In addition, sensitivity, specificity, negative predictive value and positive predictive value were calculated for each reader using the 1.25-mm sections as the gold standard. As an index for concordance the kappa value was used. A value of p<0.05 was regarded as significant. In 37 patients pulmonary nodules were detected. Twenty-four patients showed more than one nodule; among these, 7 patients had disseminated disease and were excluded from the study. Pulmonary nodules larger than 10 mm in size were equally well depicted with both modalities, whereas lesions smaller than 5 mm in size were significantly better depicted with 1.25 mm (p<0.05). Using 1.25 mm as the gold standard, sensitivity for 5-mm reconstruction interval was 88 and 86% for observers A and B, respectively. No false-positive results were reported for 5-mm sections. Interobserver agreement for nodule detection determined for 1.25-mm reconstruction intervals showed a k value of 0.753, indicating a good agreement, and 0.562 for 5-mm reconstruction intervals, indicating a moderate agreement. Brunner and Langer analysis showed significant differences for slice thickness and no significant difference between the observers. Reduced slice thickness demonstrated an improvement of small nodule detection, confidence levels, and interobserver agreement. Application of thin-slice multidetector-row CT may raise the sensitivity for lung nodule detection, although the higher detection rate of smaller nodules has to be evaluated from a clinical perspective and remains problematic about how the detection of small nodules will effect patient outcome.
A major concern about combined pulmonary CT angiography (PCTA) and CT venography (CTV) refers to the additional radiation exposure to the patient. The purpose of this paper is to analyze the organ dose, the effective dose, and the gonadal dose of combined PCTA and CTV. Effective dose and gonadal dose in PCTA and CTV were calculated. Also measured was the organ doses with thermoluminescence dosimeters in six patients who underwent combined PCTA/CTV. The risk from the effective dose and gonadal dose in combined PCTA/CTV is low. Nevertheless, additional CTV increases the gonadal dose by a significant factor and use of this procedure should be limited in younger patients.
Portal vein thrombosis (PVT) is diagnosed by imaging methods. Once diagnosed by means of ultrasound, Doppler ultrasound can be performed to distinguish between a benign and malignant thrombus. If further information is required, magnetic resonance angiography or contrast-enhanced computed tomography is the next step, and if these tests are unsatisfactory, digital subtraction angiography should be performed. Many papers have been published dealing with alternative methods of treating PVT, but the material is fairly heterogeneous. In symptomatic non-cavernomatous PVT, recanalization using local methods is recommended by many authors. Implantation of transjugular intrahepatic portosystemic shunt is helpful in cirrhotic patients with non-cavernomatous PVT in reducing portal pressure and in diminishing the risk of re-thrombosis. In noncirrhotic patients with recent PVT, some authors recommend anticoagulation alone. In chronic thrombotic occlusion of the portal vein, local measures may be implemented if refractory symptoms of portal hypertension are evident.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.