ECG-gated acquisition of 3D IVUS image sets is feasible and permits the application of automated contour detection to provide reproducible measurements of the lumen and atherosclerotic plaque CSA and volume in a relatively short analysis time.
Volumetric quantification of the vessel lumen andplaque can be derived @om a sequence of cross-sectional intracoronary ultrasound (ICUS) images. A semi-automatic approach has been developed to detect the contours of the lumen and plaque on a three-dimensional ICUS data set. This approach optimizes the contour aktection algorithm by combining information @om two perpendicular longitudinal views. Preliminary results have shown that this method is able to provide accurate and reproducible measurements of lumen and plaque volumes.
One limitation encountered using high frequency intravascular ultrasound (IVUS) is the echogenicity of blood, which increases dramatically at frequencies of 20-40 MHz. Because of the higher velocity of moving blood particles, the echo pattern of flowing blood shows more variations in time than that of the wall. To investigate the time-varying characteristics of the blood scattering measurements were performed on the radiofrequency (RF) data collected in vivo from five pig experiments. After positioning the echo catheter inside the iliac artery, an M-mode sequence of 30 RF traces was acquired at a high pulse repetition rate (5 kHz). The RF correlation time was measured on the regions of blood and the arterial wall. Two processing techniques, temporal averaging and correlation, were tested for suppression of the blood echo intensity. The correlation time Tc measured in the blood region was approximately 1 ms, which was shorter than that measured in the wall region (Tc >> 6 ms). The correlation values calculated in a small window showed a large variation in the blood region while the wall region produced a constant high output. After processing eight consecutive RF traces (delta T = 200 microseconds), the temporal averaging method results in a 50% intensity reduction in the blood region. Using the correlation output as a weighting function, the blood echo intensity can be further reduced to only 10% of its original value. Application of the RF correlation processing to a cross-sectional image data demonstrates the feasibility of this technique to remove most of the blood echoes and enhance the image contrast of the luminal interface.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.