The minimal lethal concentration of ozone in water was determined for three bacterial species:
Escherichia coli, Bacillus cereus
, and
Bacillus megaterium
. A contact period of 5 min was selected. The lethal threshold concentration for the cells of
B. cereus
was 0.12 mg/liter while that for
E. coli
and
B. megaterium
was 0.19 mg/liter. Low concentrations of ozone were ineffective when organic matter was present to interfere with the action of ozone on the bacterial cells. Also determined during the study was the sensitivity of spores of
B. cereus
and
B. megaterium
to ozone in water. The threshold concentration required to kill the spores of both species was 2.29 mg/liter. The cells and spores of these organisms exhibited the “all-or-none” die-away phenomenon normally associated with ozone treatment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.