Reliable methods for the determination of tryptophan and its metabolites are vital to the monitoring of biochemical states during the initiation and progression of cardiovascular disease. In the present study, a single-run liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the simultaneous determination of tryptophan (Trp) and its metabolites, including kynurenine (Kyn), kynurenic acid (KA), xanthurenic acid (XA) and 5-hydroxytryptamine (5-HT), in human plasma. The plasma samples were prepared using a protein precipitation approach, and the chromatographic separation was performed by gradient elution on a C column within a total analysis time of 3.5 min. The calibration ranges were 40-20,000 ng/mL for Trp, 4-2000 ng/mL for Kyn, 0.2-100 ng/mL for KA, 0.4-200 ng/mL for XA and 1-500 ng/mL for 5-HT, and the precision and accuracy were acceptable. The evaluation of recovery and internal standard-normalized matrix effect proved that the sample preparation approach was effective and the matrix effect could be negligible. The newly developed method was successfully applied to the analysis of plasma samples from healthy individuals and myocardial infarction patients. The findings suggested that the plasma concentrations of Trp, Kyn, 5-HT as well as the concentration ratios of Kyn/Trp and Trp/5-HT might serve as biomarkers for the monitoring of acute myocardial infarction.
It is currently not understood whether cigarette smoke exposure facilitates sensitisation to self-antigens and whether ensuing auto-reactive T cells drive chronic obstructive pulmonary disease (COPD)-associated pathologies.To address this question, mice were exposed to cigarette smoke for 2 weeks. Following a 2-week period of rest, mice were challenged intratracheally with elastin for 3 days or 1 month. Rag1−/−, Mmp12−/−, and Il17a−/− mice and neutralising antibodies against active elastin fragments were used for mechanistic investigations. Human GVAPGVGVAPGV/HLA-A*02:01 tetramer was synthesised to assess the presence of elastin-specific T cells in patients with COPD.We observed that 2 weeks of cigarette smoke exposure induced an elastin-specific T cell response that led to neutrophilic airway inflammation and mucus hyperproduction following elastin recall challenge. Repeated elastin challenge for 1 month resulted in airway remodelling, lung function decline and airspace enlargement. Elastin-specific T cell recall responses were dose dependent and memory lasted for over 6 months. Adoptive T cell transfer and studies in T cells deficient Rag1−/−mice conclusively implicated T cells in these processes. Mechanistically, cigarette smoke exposure-induced elastin-specific T cell responses were matrix metalloproteinase (MMP)12-dependent, while the ensuing immune inflammatory processes were interleukin 17A-driven. Anti-elastin antibodies and T cells specific for elastin peptides were increased in patients with COPD.These data demonstrate that MMP12-generated elastin fragments serve as a self-antigen and drive the cigarette smoke-induced autoimmune processes in mice that result in a bronchitis-like phenotype and airspace enlargement. The study provides proof of concept of cigarette smoke-induced autoimmune processes and may serve as a novel mouse model of COPD.
This study investigated the influence of thread pitch, helix angle, and compactness on micromotion in immediately loaded implants in bone of varying density (D2, D3, and D4). Five models of the three-dimensional finite element (0.8 mm pitch, 1.6 mm pitch, 2.4 mm pitch, double-threaded, and triple-threaded implants) in three types of bone were created using Pro/E, Hypermesh, and ABAQUS software. The study had three groups: Group 1, different pitches (Pitch Group); Group 2, same compactness but different helix angles (Angle Group); and Group 3, same helix angle but different compactness (Compact Group). Implant micromotion was assessed as the comprehensive relative displacement. We found that vertical relative displacement was affected by thread pitch, helix angle, and compactness. Under vertical loading, displacement was positively correlated with thread pitch and helix angle but negatively with compactness. Under horizontal loading in D2, the influence of pitch, helix angle, and compactness on implant stability was limited; however, in D3 and D4, the influence of pitch, helix angle, and compactness on implant stability is increased. The additional evidence was provided that trabecular bone density has less effect on implant micromotion than cortical bone thickness. Bone type amplifies the influence of thread pattern on displacement.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.