Two simple and sensitive high performance liquid chromatography–tandem mass spectrometry (HPLC–MS/MS) methods were developed and validated for the determination of fenticonazole in human plasma after percutaneous and intravaginal administration. Mifepristone was used as an internal standard (IS), and simple protein precipitation by acetonitrile containing 2% acetic acid was utilized for extracting the analytes from the plasma samples. Chromatographic separation was performed on a Kinetex XB-C18 column. The quantitation was performed by a mass spectrometer equipped with an electrospray ionization source in multiple reactions monitoring (MRM) positive ion mode using precursor-to-product ion transitions of m/z 455.2–199.1 for fenticonazole and m/z 430.2–372.3 for mifepristone. The validated linear ranges were 5–1000 pg/mL and 0.1–20 ng/mL fenticonazole in plasma for the methods A and B, respectively. For the two methods, the accuracy data ranged from 85% to 115%, the intra- and inter-batch precision data were less than 15%, the recovery data were more than 90%, and no matrix interference was observed. The methods A and B were successfully validated and applied to the pharmacokinetic studies of fenticonazole gel in Chinese healthy volunteers after percutaneous and intravaginal administration, respectively.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.