Abstract-Due to high-density routing under the CPU and DIMM areas, the original design of even and odd mode characteristic impedances changes. The occurrence of multi-drop problem between the CPU and memory chip causes over-and under-driven that reduce the eye opening. Furthermore, the different phase velocities of evenand odd-modes cause timing jitter at the receiver end. This paper proposes two steps to solve the complex issue of signal integrity for the multi-module memory bus. First, particle swarm optimization (PSO) is used to tune the characteristic impedance of the transmission line and on-die termination (ODT) values to improve transmission line impedance changes to obtain maximum power delivery. The fitness function of the algorithm is defined by selecting the minimum reflection coefficient at the driver side and maximum the transmission coefficient at the receiver side to reduce the over-and under-driven Second, the timing jitter can be reduced by placing a capacitor to compensate for the velocity difference caused by different propagation modes. Finally, signal integrity enhancements for the DDR3 are verified by measuring S parameters in the frequency domain and postprocessed eye diagrams in the time domain.
The accuracy and stability of dynamometer diagram measurement are key assessment index for this technology. At present, separator measurement data is mostly taken as comparison benchmark for evaluation of dynamometer diagram measurement in Huabei Oilfield, resulting in large error in comparison. In view of existence of gas, water and pressure, gas/liquid separation of produced fluid is followed by separating measurement of gas and liquid. Gas and liquid mixture are measured by flow meter and weighing method, respectively. Higher precision measurement data is obtained. In combination with PLC programming control, this technology can realize fully automatic and continuous measurement. This device has been applied in 126 wells in Huabei Oilfield. Assisted by dynamometer diagram measurement software, point-to-point calibration and correction method of yield measurement is improved[.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.