Background: The national programs for the harmonization of hemoglobin (Hb)A1c measurements in the US [National Glycohemoglobin Standardization Program (NGSP)], Japan [Japanese Diabetes Society (JDS)/Japanese Society of Clinical Chemistry (JSCC)], and Sweden are based on different designated comparison methods (DCMs). The future basis for international standardization will be the reference system developed by the IFCC Working Group on HbA1c Standardization. The aim of the present study was to determine the relationships between the IFCC Reference Method (RM) and the DCMs. Methods: Four method-comparison studies were performed in 2001–2003. In each study five to eight pooled blood samples were measured by 11 reference laboratories of the IFCC Network of Reference Laboratories, 9 Secondary Reference Laboratories of the NGSP, 3 reference laboratories of the JDS/JSCC program, and a Swedish reference laboratory. Regression equations were determined for the relationship between the IFCC RM and each of the DCMs. Results: Significant differences were observed between the HbA1c results of the IFCC RM and those of the DCMs. Significant differences were also demonstrated between the three DCMs. However, in all cases the relationship of the DCMs with the RM were linear. There were no statistically significant differences between the regression equations calculated for each of the four studies; therefore, the results could be combined. The relationship is described by the following regression equations: NGSP-HbA1c = 0.915(IFCC-HbA1c) + 2.15% (r2 = 0.998); JDS/JSCC-HbA1c = 0.927(IFCC-HbA1c) + 1.73% (r2 = 0.997); Swedish-HbA1c = 0.989(IFCC-HbA1c) + 0.88% (r2 = 0.996). Conclusion: There is a firm and reproducible link between the IFCC RM and DCM HbA1c values.
HbA1C is the stable glucose adduct to the N-terminal group of the beta-chain of HbA0. The measurement of HbA1c in human blood is most important for the long-term control of the glycaemic state in diabetic patients. Because there was no internationally agreed reference method the IFCC Working Group on HbA1c Standardization developed a reference method which is here described. In a first step haemoglobin is cleaved into peptides by the enzyme endoproteinase Glu-C, and in a second step the glycated and non-glycated N-terminal hexapeptides of the beta-chain obtained are separated and quantified by HPLC and electrospray ionisation mass spectrometry or in a two-dimensional approach using HPLC and capillary electrophoresis with UV-detection. Both principles give identical results. HbA1c is measured as ratio between the glycated and non-glycated hexapeptides. Calibrators consisting of mixtures of highly purified HbA1c and HbA0 are used. The analytical performance of the reference method has been evaluated by an international network of reference laboratories comprising laboratories from Europe, Japan and the USA. The intercomparison studies of the network showed excellent results with intra-laboratory CVs of 0.5 to 2% and inter-laboratory CVs of 1.4 to 2.3%. Possible interferences have been carefully investigated. Due to the higher specificity of the reference method the results are lower than those generated with most of the present commercial methods which currently are calibrated with unspecific designated comparison methods. The new reference method has been approved by the member societies of the International Federation of Clinical Chemistry and Laboratory Medicine and will be the basis for the future uniform standardization of HbA1c routine assays worldwide.
This paper is the fourth in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 5. Reference Procedure for the Measurement of Catalytic Concentration of Aspartate Aminotransferase; Part 6. Reference Procedure for the Measurement of Catalytic Concentration of Gamma-Glutamyltransferase; Part 7. Certification of Four Reference Materials for the Determination of Enzymatic Activity of Gamma-Glutamyltransferase, Lactate Dehydrogenase, Alanine Aminotransferase and Creatine Kinase at 37 degrees C. A document describing the determination of preliminary upper reference limits is also in preparation. The procedure described here is deduced from the previously described 30 degrees C IFCC reference method. Differences are tabulated and commented on in Appendix 2.
This paper is the fifth in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine Aminotransferase; Part 6. Reference Procedure for the Measurement of Catalytic Concentration of Gamma-Glutamyltransferase; Part 7. Certification of Four Reference Materials for the Determination of Enzymatic Activity of Gamma-Glutamyltransferase, Lactate Dehydrogenase, Alanine Aminotransferase and Creatine Kinase at 37 degrees C. A document describing the determination of preliminary upper reference limits is also in preparation. The procedure described here is deduced from the previously described 30 degrees C IFCC reference method. Differences are tabulated and commented on in Appendix 3.
This paper is the sixth in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine Aminotransferase; Part 5. Reference Procedure for the Measurement of Catalytic Concentration of Aspartate Aminotransferase; Part 7. Certification of Four Reference Materials for the Determination of Enzymatic Activity of Gamma-Glutamyltransferase, Lactate Dehydrogenase, Alanine Aminotransferase and Creatine Kinase at 37 degrees C A document describing the determination of preliminary upper reference limits is also in preparation. The procedure described here is deduced from the previously described 30 degrees C IFCC reference method. Differences are tabulated and commented on in Appendix 1.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.