This report describes pressure comparison measurements in the range 0.07 MPa to 0.4 MPa between the Czech Institute of Metrology (CMI) and the Physikalisch-Technische Bundesanstalt (PTB) in the period 9 to 13 March 1998 at the Pressure Section of the PTB, Braunschweig. The transfer standard used was a gasoperated piston-cylinder assembly with a ceramic piston of nominal effective area 10 cm 2 and a tungsten-carbide cylinder, installed in a pressure balance base unit, model PG 7601, manufactured by DH Instruments, USA. The measurements compare the effective area of the transfer piston-cylinder assembly as determined from dimensional data at the CMI with effective area data obtained from pressure measurements (i) in gauge mode with the primary standard pressure balance and (ii) in absolute and gauge mode with the primary standard dual-cistern mercury manometer of the PTB. Both primary standard instruments have been used in the international comparison measurements organized by the Consultative Committee for Mass and Related Quantities (CCM) of the Comité International des Poids et Mesures. It may be seen that geometrical measurement values of the effective area agree with results from the PTB and that the relative difference between the effective area is minimal: for the standard pressure balance, 3.4 10 -6 for absolute pressure, 3.4 10 -6 for gauge pressure; and for the dual-cistern mercury manometer, 1.8 10 -6 for gauge mode. The relative difference between the experimental absolute and gauge mode for the dual-cistern mercury manometer is 1.5 10 -6 .
This report describes the results of a supplementary comparison of hydraulic high-pressure standards at two national metrology institutes (NMIs) – National Metrology Institute of Japan, AIST (NMIJ/AIST) and Physikalisch-Technische Bundesanstalt (PTB), Germany – which was carried out during the period January 2007 to March 2007 within the framework of the Asia-Pacific Metrology Programme (APMP) and the European Association of National Metrology Institutes (EURAMET) in order to determine their degrees of equivalence at pressures in the range 100 MPa to 1000 MPa for gauge mode.The pilot institute was NMIJ/AIST. NMIJ/AIST used a hydraulic pressure balance and a pressure multiplier, and PTB used a controlled-clearance pressure balance as their pressure standards. High-precision pressure transducers were used as a transfer standard. The sensing element of the transducers was a foil strain gauge. To ensure the reliability of the transfer standard, two pressure transducers were used on the transfer standard unit. At the beginning and the end of this comparison, the transfer standard was calibrated at the pilot institute.From the calibration results, the behaviour of the transfer standard during the comparison period was characterized and it was found that the capability of the transfer standard for the purpose of this supplementary comparison was sufficient. The degrees of equivalence of the national measurement standards were expressed in terms of deviations from the supplementary comparison reference values and from each other, considered in combination with associated uncertainties of these deviations. The hydraulic pressure standards in the range 100 MPa to 1000 MPa for gauge mode of the two participating NMIs were found to be equivalent within their claimed uncertainties.Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.The final report has been peer-reviewed and approved for publication by APMP, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
No abstract
No abstract
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.