A combination of the fastest time course and lowest consumption of sevoflurane and desflurane was found when using the Zeus apparatus in AC uptake mode.
SummaryThe Zeus Ò anaesthesia machine includes an auto-control mode which allows targeting of end-tidal volatile and inspired oxygen concentrations. We assessed the clinical benefits and economic impact of this target-controlled anaesthesia compared with conventional manually controlled anaesthesia. Eighty patients were randomly assigned to receive desflurane either with a fresh gas flow set by the anaesthetist or in auto-control mode. Drug delivery was adjusted to maintain bispectral index between 40-60 units and systolic arterial pressure under 15 mmHg above its pre-induction value (upper limit) and over 90 mmHg (lower limit). Blood pressure was maintained in the desired range for 89% and 91% of the maintenance period for auto-control and manual control respectively (p = 0.49). Bispectral index was in the desired range for 82% and 79% of the maintenance period, for auto-control and manual control respectively (p = 0.46). Oxygen consumption was more than halved by the use of auto-control mode, and mean (SD) desflurane consumption during surgery was 0.07 (0.04) vs 0.2 (0.07) ml.min
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.