To evaluate whether acute myocardial dysfunction was common in the early postoperative period, serial hemodynamic measurements and radionuclide evaluation of ventricular function were performed before and after operation in 24 patients undergoing elective coronary bypass surgery. All patients had uncomplicated surgery, and no patient sustained an intraoperative infarction. In 96% of patients, significant depression in right and left ventricular ejection fraction was seen postoperatively, reaching a nadir at 262 +/- 116 min after coronary bypass. Left ventricular ejection fraction was 58 +/- 12% preoperatively and 37 +/- 10% at trough. Right ventricular function displayed a similar pattern. These findings were also associated with depressed cardiac and left ventricular stroke work index despite maintenance of adequate ventricular filling pressures and mean arterial pressure. The depression in ventricular function was partially reversible within 8 to 10 h after surgery. Left ventricular ejection fraction had increased to 55 +/- 13% at 426 +/- 77 min after coronary bypass and showed complete recovery within 48 h. Left ventricular end-systolic and end-diastolic volume index increased significantly postoperatively, but recovery in left ventricular ejection fraction was mostly due to decreases in end-systolic volume index (50 +/- 22 ml at trough and 32 +/- 16 ml at recovery). Depressed myocardial function was independent of bypass time, number of grafts placed, preoperative medications or core temperatures postoperatively. Postoperative therapy with pressors or inotropic agents delayed but did not prevent the occurrence of postoperative ventricular dysfunction. Despite improvements in operative techniques and methods of myocardial protection, postoperative left ventricular dysfunction continues to be common in patients undergoing cardiopulmonary bypass surgery.(ABSTRACT TRUNCATED AT 250 WORDS)
To investigate cardiopulmonary function in progressive systemic sclerosis with diffuse scleroderma, we studied 26 patients with maximal exercise and redistribution thallium scans, rest and exercise radionuclide ventriculography, pulmonary-function testing, and chest roentgenography. Although only 6 patients had clinical evidence of cardiac involvement, 20 had abnormal thallium scans, including 10 with reversible exercise-induced defects and 18 with fixed defects (8 had both). Seven of the 10 patients who had exercise-induced defects and underwent cardiac catheterization had normal coronary angiograms. Mean resting left ventricular ejection fraction and mean resting right ventricular ejection fraction were lower in patients with post-exercise left ventricular thallium defect scores above the median (59 +/- 13 per cent vs. 69 +/- 6 per cent [P less than 0.025], and 36 +/- 12 per cent vs. 47 +/- 7 per cent [P less than 0.025], respectively). We conclude that in progressive systemic sclerosis with diffuse scleroderma, abnormalities of myocardial perfusion are common and appear to be due to a disturbance of the myocardial microcirculation. Both right and left ventricular dysfunction appear to be related to this circulatory disturbance, suggesting ischemically mediated injury.
Background-Soft tissue attenuation is a prominent cause of single-photon emission computed tomography (SPECT) imaging artifacts, which may result in reduced diagnostic accuracy of myocardial perfusion imaging. A method incorporating simultaneously acquired transmission data permits nonuniform attenuation correction and when incorporating scatter correction and resolution compensation may substantially reduce interpretive errors. Methods and Results-A prospective multicenter trial was performed recruiting patients with angiographically documented coronary disease (nϭ96) and group of subjects with a low likelihood of disease (nϭ88). The uncorrected and attenuation/scatter corrected images were read independently, without knowledge of the patient's clinical data. The detection of Ն50% stenosis was similar using uncorrected perfusion data or with attenuation/ scatter correction and resolution compensation (visual or visual plus quantitative analysis), 76% versus 75% versus 78%, respectively (PϭNS). The normalcy rate, however, was significantly improved with this new methodology, using either the corrected images (86% vs 96%; Pϭ0.011) or with the corrected data and quantitative analysis (86% vs 97%; Pϭ0.007). The receiver operator characteristic curves were also found to be marginally but not significantly higher with attenuation/scatter correction than with tradition SPECT imaging. However, the ability to detect multivessel disease was reduced with attenuation/scatter correction. Regional differences were also noted, with reduced sensitivity but improved specificity for right coronary lesions using attenuation/scatter correction methodology.
Conclusions-This multicenter trial demonstrates the initial clinical results of a new SPECT perfusion imaging modalityincorporating attenuation and scatter correction in conjunction with 99m Tc sestamibi perfusion imaging. Significant improvements in the normalcy rate were noted without a decline in overall sensitivity but with a reduction in detection of extensive coronary disease. (Circulation. 1999;99:2742-2749.)
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.