An error correction model for ultrasonic gas flowmeter was proposed to explore the potential of an ultrasonic flowmeter for metering gas-liquid stratified and annular flows. The gas and liquid mass flowrates could be obtained provided that the gas quality and physical prosperities were known. A single-path ultrasonic flowmeter was investigated and the error of the apparent volumetric flowrate was considered as mainly resulting from the shrinkage of the gas flow path due to the presence of a liquid phase. Fourteen void fraction models were selected for the stratified and annular flows and evaluated against experimental data. It was demonstrated that the root-mean-square error of the gas mass flowrate can be reduced from 19.0% to below 5% by employing either of Lockhart & Martinelli, Baroczy, Spedding & Chen, or Wallis void fraction models. Lockhart & Martinelli model is recommended due to its higher accuracy, simpler formulation, sounder theoretical support, and stronger immunity to pressure variation. The error correction model proposed in this work provides a basis for developing new combination measurement methods with an ultrasonic flowmeter as one component.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.