The detection of chemical mapping with a spatial resolution of 30 nm has been achieved with a scanning transmission X-ray microscope at the Shanghai Synchrotron Radiation Facility. For each specimen, two absorption images were scanned separately with energies E(1) and E(2): E(1) was focused on the absorption edge of the chosen element and E(2) was focused below the edge. A K-edge division method is proposed and applied to obtain the element mapping. Compared with the frequently used K-edge subtraction method, this ratio-contrast method is shown to be more accurate and sensitive in identifying the elements of interest, where the definition of the contrast threshold is simple and clear in physics. Several examples are presented to illustrate the effectiveness of the method.
Compared with traditional de-ionized pressurized-water cooled magnet of ECRIS, evaporative cooling magnet has some special characteristics, such as high cooling efficiency, simple maintenance, and operation. The analysis is carried out according to the design and operation of LECR4 (Lanzhou Electron Cyclotron Resonance ion source No. 4, since July 2013), whose magnet is cooled by evaporative cooling technology. The insulation coolant replaces the de-ionized pressurized-water to absorb the heat of coils, and the physical and chemical properties of coolant remain stable for a long time with no need for purification or filtration. The coils of magnet are immersed in the liquid coolant. For the higher cooling efficiency of coolant, the current density of coils can be greatly improved. The heat transfer process executes under atmospheric pressure, and the temperature of coils is lower than 70 °C when the current density of coils is 12 A/mm(2). On the other hand, the heat transfer temperature of coolant is about 50 °C, and the heat can be transferred to fresh air which can save cost of water cooling system. Two years of LECR4 stable operation show that evaporative cooling technology can be used on magnet of ECRIS, and the application advantages are very obvious.
An emittance scanner named Electric-Sweep Scanner had been designed and fabricated in IMP. And it has been set up on the LECR3 beam line for the ion beam quality study. With some development, the ESS system has become a relatively dependable and reliable emittance scanner. Its experiment error is about 10 percent. We have done a lot of experiments of emittance measurement on LECR3 ion source, and have researched the relations between ion beam emittance and the major parameters of ECR ion source. The reliability and accuracy test results are presented in this paper. And the performance analysis is also discussed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.