A screen-printed carbon nanotube (CNTs) based disposable third generation biosensor for hydrogen peroxide (H 2 O 2 ) was constructed by mixing CNTs with a cellulose acetate binder on an epoxy substrate. The surface was covered with a layer consisting of horseradish peroxidase (HRP) crosslinked to bovine serum albumin with glutaraldehyde. The CNTs acted as both the electrode material and charge promoter to facilitate the direct electron transfer between immobilized HRP and the modified electrode. At a working potential of −300 mV (vs. Ag/AgCl), the biosensor displays an excellent electrocatalytic response to the reduction of H 2 O 2 without the aid of a mediator. It has a fast (3 s) amperometric response and a linear calibration in the concentration range 0.005-0.1 mmol L −1 , with a 0.85 μM detection limit (at an S/ N of 3). The biosensor can be easily produced, is stable and reproducible.
Two fluorescent anion sensors bearing phenol, carbazole-NH and -NO 2 group were designed and synthesized. They both exhibited highly binding ability for , respectively. Theoretical investigation indicated it was the highest HOMO to induce the red-shift phenomena of two sensors.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.