The aim of this study was to examine if walking periods and number of steps can accurately be detected by a single small body-fixed device in older adults and patients with Parkinson's disease (PD). Results of an accelerometry-based method (DynaPort MicroMod) and a pedometer (Yamax Digi-Walker SW-200) worn on each hip were evaluated against video observation. Twenty older adults and 32 PD patients walked straight-line trajectories at different speeds, of different lengths and while doing secondary tasks in an indoor hallway. Accuracy of the instruments was expressed as absolute percentage error (older adults versus PD patients). Based on the video observation, a total of 236.8 min of gait duration and 24,713 steps were assessed. The DynaPort method predominantly overestimated gait duration (10.7 versus 11.1%) and underestimated the number of steps (7.4 versus 6.9%). Accuracy decreased significantly as walking distance decreased. Number of steps were also mainly underestimated by the pedometers, the left Yamax (6.8 versus 11.1%) being more accurate than the right Yamax (11.1 versus 16.3%). Step counting of both pedometers was significantly less accurate for short trajectories (3 or 5 m) and as walking pace decreased. It is concluded that the Yamax pedometer can be reliably used for this study population when walking at sufficiently high gait speeds (>1.0 m/s). The accelerometry-based method is less speed-dependent and proved to be more appropriate in the PD patients for walking trajectories of 5 m or more.
IntroductionThe aim of this study was to investigate the construct validity and test-retest reliability of the International Physical Activity Questionnaire (IPAQ; long form) and the Short QUestionnaire to Assess Health-enhancing physical activity (SQUASH) and to investigate the relation between daily physical activity and clinical assessments in patients with ankylosing spondylitis (AS).MethodsFor validity, the self-report questionnaires IPAQ and SQUASH were compared with daily physical activity assessed with the ActiGraph accelerometer during 7 consecutive days in 63 AS outpatients. For reliability, the IPAQ and SQUASH were administered twice approximately 1 week apart in 52 AS outpatients. In all 115 patients, clinical assessments were performed at the outpatient clinic.ResultsIPAQ and SQUASH total scores correlated significantly with accelerometer outcome: ρ = 0.38 and r = 0.35, respectively. Intraclass correlation coefficients between first and second assessments of the IPAQ and SQUASH were 0.83 and 0.89, respectively. Bland-Altman analyses showed no systemic bias, but in particular for the IPAQ the 95% limits of agreement were wide. Daily physical activity assessed by accelerometer, IPAQ, and SQUASH correlated significantly with disease activity, physical activity, and quality of life. A relation with spinal mobility was found only for the accelerometer and SQUASH. The direction of these correlations indicates that higher daily physical activity is related to lower disease activity and better physical function, spinal mobility and quality of life.ConclusionsBoth physical activity questionnaires showed modest construct validity. The SQUASH showed good test-retest reliability, superior to the IPAQ. These results indicate that the SQUASH is more suitable than the IPAQ to assess daily physical activity in AS population studies. However, it is desirable to add questions on AS-specific physical activity. Further studies are needed to investigate the causality of the relation between daily physical activity and clinical assessments.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.