Objectives
We validate the use of a lateral flow immunoassay (LFI) intended for rapid screening and qualitative detection of anti-SARS-CoV-2 IgM and IgG in serum, plasma, and whole blood, and compare results with ELISA. We also seek to establish the value of LFI testing on blood obtained from a capillary blood sample.
Methods
Samples collected by venous blood draw and finger stick were obtained from patients with SARS-CoV-2 detected by RT-qPCR and control patients. Samples were tested with Biolidics 2019-nCoV IgG/IgM Detection Kit lateral flow immunoassay, and antibody calls were compared with ELISA.
Results
Biolidics LFI showed clinical sensitivity of 92% with venous blood at 7 days after PCR diagnosis of SARS-CoV-2. Test specificity was 92% for IgM and 100% for IgG. There was no significant difference in detecting IgM and IgG with Biolidics LFI and ELISA at D0 and D7 (
p
= 1.00), except for detection of IgM at D7 (
p
= 0.04). Capillary blood of SARS-CoV-2 patients showed 93% sensitivity for antibody detection.
Conclusions
Clinical performance of Biolidics 2019-nCoV IgG/IgM Detection Kit is comparable to ELISA and was consistent across sample types. This provides an opportunity for decentralized rapid testing and may allow point-of-care and longitudinal self-testing for the presence of anti-SARS-CoV-2 antibodies.
Objectives: Numerous serologic immunoassays have been launched to detect antibodies to SARS-CoV-2, including rapid tests. Here, we validate use of a lateral flow immunoassay (LFI) intended for rapid screening and qualitative detection of anti-SARS-CoV-2 IgM and IgG in serum, plasma, and whole blood, and compare results with ELISA. We also seek to establish the value of LFI testing on blood obtained from a capillary blood sample.
Methods:Samples collected by venous blood draw and capillary finger stick were obtained from patients with SARS-CoV-2 detected by RT-qPCR and control patients negative for SARS-CoV-2. Samples were tested with the 2019-nCoV IgG/IgM Detection Kit (Colloidal Gold) lateral flow immunoassay, and antibody calls were compared with results obtained by ELISA.
Results:The Biolidics LFI kit shows clinical sensitivity of 92% at 7 days after PCR diagnosis of SARS-CoV-2 on venous blood. Test specificity was 92% for IgM and 100% for IgG. There was no significant difference in detecting IgM and IgG with Biolidics LFI and ELISA at D0 and D7 (p=1.00), except for detection of IgM at D7 (p=0.04). Finger stick whole blood of SARS-CoV-2 patients showed 93% sensitivity for antibody detection.
Conclusions:Clinical performance of Biolidics 2019-nCoV IgG/IgM Detection Kit (Colloidal Gold) is comparable to ELISA and showed consistent results across different sample types. Furthermore, we show that capillary blood obtained by finger stick shows similar sensitivity for detecting anti-SARS-CoV-2 IgM and IgG antibodies as venous blood samples. This provides an opportunity for decentralized rapid testing in the community and may allow point-of-care and longitudinal self-testing for the presence of anti-SARS-CoV-2 antibodies.
Conjugates of small molecule and antibodies are broadly employed diagnostic and therapeutic agents. Appending a small molecule to an antibody often significantly impacts the properties of the resulting conjugate. Here we detail a systematic study investigating the effect of various functional groups on the properties of antibody-fluorophore conjugates. This was done through the preparation and analysis of a series of masked heptamethine cyanines (CyMasks) bearing amides with varied functional groups. These were designed to exhibit a broad range of physical properties, and include hydrophobic (-NMe2), pegylated (NH-PEG-8 or NH-PEG-24), cationic (NH-(CH2)2NMe3+) anionic (NH-(CH2)2SO3-), and zwitterionic (N-(CH2)2NMe3+)-(CH2)3SO3-) variants. The CyMask series was appended to tumor targeting monoclonal antibodies (mAbs) and analyzed for effects on tumor targeting, clearance and non-specific organ uptake. Among the series, zwitterionic and cationic dye conjugates showed the highest tumor-to-background ratio (TBR), although the latter also exhibited an elevated liver-to-background ratio (LBR). Overall, these studies provide a strategy to test the functional group effects and suggest that zwitterionic substituents are an attractive strategy to mask hydrophobic payloads, with the potential to improve the properties of bioconjugates in vivo.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.