Objective: To evaluate the computational biomechanical analysis of intra-articular calcaneal fractures with different fixation status of the sustentaculum plate screw, when the finite element modeling of calcaneal fractures were fixed by the lateral locking plate. Methods:The normal right foot of a male (age: 36 years; height: 174 cm; body weight: 65 kg) was scanned by the CT scanner. As the computational biomechanical study, the three-dimensional finite element model of the simplified Sanders type-II calcaneal fracture was built. Fixation with the lateral calcaneal locking plate and screws was simulated using a finite element software package according to clinical operation. According to the different placement of the sustentaculum plate screw, the models were categorized as the accurate fixation group, marginal fixation group, and non-fixation group. The loading of 650 N with the vertical axial compression was applied to simulate the standing phase with single foot. The Von Mises stress distribution, maximal displacement, and contact area of the subtalar joint were analyzed among three groups. Results:The pressure distribution of the subtalar joint facet was inhomogeneous. The stress concentration of the calcaneus was located at the medial zone of the posterior subtalar joint facet. The peak Von Mises stress distribution in three groups was similar at the subtalar joint facet of 4.9 MPa, 5.1 MPa, and 5.4 MPa. In the accurate fixation group, the contact area on the posterior articular facet was 277.1 mm 2 ; the maximal displacement was 0.18 mm. The contact area of the marginal fixation group was 265.3 mm 2 on the posterior facet, where the maximal displacement was 0.23 mm. In the non-fixation group, the contact area was 253.8 mm 2 ; the maximal displacement was 0.25 mm. There was a slight change in the contact area of the subtalar joint and no prominent displacement of the calcaneus could be detected among the three groups. Conclusions:The biomechanical results, including the peak stress distribution, contact area, and maximal displacement of subtalar joint, were similar whether the screw is placed exactly within the sustentaculum tali or not, when the calcaneal fractures were fixed by the lateral locking plate. The sustentaculum plate screw had less effect on the biomechanical performance of the calcaneus.
Background: The extramedullary locking plate system was the common internal fixation method for hip fractures. However, common plates were poorly matched to femur, which was because they were designed based on anatomical parameters of the Western populations. Therefore, the aim was to design an end-structure of the anatomical proximal femoral locking plate that closely matched the anatomy of the Chinese population. Materials and methods: From January 2010 to December 2021, consecutive patients aged 18 years and older who underwent a full-length computed tomography scan of the femur were included. The end-structure (male and female model) of the anatomical proximal femoral locking plate was designed based on anatomical parameters of femurs that were measured in three-dimensional space using computer-assisted virtual technology. The match degree between the end-structure and femur were evaluated. Inter-observer and intra-observer agreement for the evaluation of match degree was assessed. The matching evaluation based on a three-dimensional printing model was regarded as the gold standard to assess the reliability. Results: A total of 1672 patients were included, with 701 men and 971 women. Significant differences were seen between male and female for all parameters of the proximal femur (all P<0.001). All match degree of end-structure was over 90%. Inter-observer and intra-observer agreement was almost perfect (all kappa value, >0.81). The sensitivity, specificity, and percentage of correct interpretation of matching evaluation in the computer-assisted virtual model was all greater than 95%. From femur reconstruction to completion of internal fixation matching, the process takes about 3 min. Moreover, reconstruction, measurement, and matching were all completed in one system. Conclusions: The results showed that based on the larger sample of femoral anatomical parameters, a highly matching end-structure of anatomical proximal femoral locking plate for Chinese population could be designed with use of computer-assisted imaging technology.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.