BackgroundThis study examined the effect of treatment with a novel biomechanical device on the level of pain and function in patients with knee OA.MethodsPatients with bilateral knee OA were enrolled to active and control groups. Patients were evaluated at baseline, at 4 weeks and at the 8-week endpoint. A novel biomechanical device was individually calibrated to patients from the active group. Patients from the control group received an identical foot-worn platform without the biomechanical elements. Primary outcomes were the WOMAC Index and ALF assessments.ResultsThere were no baseline differences between the groups. At 8 weeks, the active group showed a mean improvement of 64.8% on the WOMAC pain scale, a mean improvement of 62.7% on the WOMAC function scale, and a mean improvement of 31.4% on the ALF scale. The control group demonstrated no improvement in the above parameters. Significant differences were found between the active and control groups in all the parameters of assessment.ConclusionsThe biomechanical device and treatment methodology is effective in significantly reducing pain and improving function in knee OA patients.The study is registered at clinicaltrials.gov, identifier NCT00457132, http://www.clinicaltrials.gov/ct/show/NCT00457132?order=1
Iatrogenic vascular complications following elective THR and TKR carry a risk of significant morbidity and mortality. It is important that surgeons and trainees performing these procedures are conscious of these risks and able to identify vascular injuries promptly when they occur. Detailed preoperative assessment, an awareness of anatomical variants and close liaison with a vascular surgeon may all help to reduce the number and severity of adverse outcomes.
Several biomechanics treatments for knee osteoarthritis (OA) have emerged with the goal of reducing pain and improving function. Through this, researchers have hoped to achieve a transition from the pathological gait patterns to coordinated motor responses. The purpose of the study was to determine the long-term effects of a therapy using a biomechanical device in patients with knee OA. Patients with knee OA were enrolled to active and control groups. The biomechanical device used in therapy (AposTherapy) was individually calibrated to each patient in the active group. Patients in the control group received standard treatment. Outcomes were the Western Ontario and McMaster Osteoarthritis Index (WOMAC), Aggregated Locomotor Function (ALF), Short Form 36 (SF-36), and Knee Society Score assessments. The active and control groups were similar at the baseline (group difference in all scores P > 0.05). The active group showed a larger improvement over time between groups in all three WOMAC categories (F = 16.8, 21.7, and 18.1 for pain, stiffness, and function; all P < 0.001), SF-36 Physical Scale (F = 5.8; P = 0.02), Knee Society Knee Score (F = 4.3; P = 0.044
), and Knee Society Function Score (F = 6.5; P = 0.014
). At the two-year endpoint, the active group showed significantly better results (all P ≤ 0.001). The groups showed a difference of 4.9, 5.6, and 4.7 for the WOMAC pain, stiffness, and function scores, respectively, 10.8 s in ALF score, 30.5 in SF-36 Physical Scale, 16.9 in SF-36 Mental Scale, 17.8 in Knee Society Knee Score, and 25.2 in Knee Society Function Score. The biomechanical therapy examined was shown to significantly reduce pain and improve function and quality of life of patients with knee OA over the long term.
BackgroundThe purpose of the study was to examine the effect of a foot-worn biomechanical device on the clinical measurements and gait patterns of patients with total hip arthroplasty (THA).MethodsNineteen patients, up to 3 months post-THA, were enrolled to the study. Patients underwent a computerized gait analysis to calculate spatiotemporal parameters and completed the Western Ontario and McMaster Universities osteoarthritis index and the SF-36 health survey. Patients then began therapy with a non-invasive foot-worn biomechanical device coupled with a treatment methodology (AposTherapy). Patients received exercise guidelines and used the device daily during their regular activities at their own environment. Follow-up examinations were conducted after 4, 12, and 26 weeks of therapy. Repeated measures ANOVA was used to evaluate changes over time. The clinical significance of the treatment effect was evaluated by computing the Cohen's effect sizes (ES statistic).ResultsAfter 26 weeks of therapy, a significant improvement was seen in gait velocity (50.3%), involved step length (22.9%), and involved single limb support (16.5%). Additionally, a significant reduction in pain (85.4%) and improvement in function (81.1%) and quality of life (52.1%) were noted.ConclusionsPatients following THA demonstrated a significant improvement in gait parameters and in self-assessment evaluations of pain, function, and quality of life. We recommend further RCTs to examine the effect of this therapy compared to other rehabilitation modalities following THA and compared to healthy matched controls.Trial registrationClinical trial registration number NCT01266382
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.