Degraded carrageenan (known as poligeenan molecular weight: 20 kDa to 30 kDa) causes ulcerative colitis in experimental animals. In this paper, the molecular weight distributions of 29 samples of food-grade refined carrageenans were studied by high performance liquid gel permeation chromatography (GPC) directly connected to vacuum-ultraviolet inductively coupled plasma-atomic emission spectrometry (ICP) (GPC/ICP) as well as GPC/refractive index (RI) detection. All samples of food-grade carrageenan had a major broad peak of high molecular weight which eluted at around 6.5 min in both RI and ICP mode (sulphur and carbon), and each sample of them had no obvious peak of poligeenan (the detection limit was about 5%). The number average molecular weights of these carrageenans ranged from 193 kDa to 324 kDa, and the weight average molecular weights ranged from 453 kDa to 652 kDa based on RI data. Some samples had a few minor peaks which eluted around 10-12 min. These peaks came from ionic sulphate, sucrose or glucose. It was considered that if the data-sampling programme was improved, the GPC/ICP system would become a more powerful technique for evaluation of carrageenan samples containing ionic substances and sugar.
Degraded carrageenan (known as poligeenan molecular weight: 20 kDa to 30 kDa) causes ulcerative colitis in experimental animals. In this paper, the molecular weight distributions of 29 samples of food-grade refined carrageenans were studied by high performance liquid gel permeation chromatography (GPC) directly connected to vacuum-ultraviolet inductively coupled plasma-atomic emission spectrometry (ICP) (GPC/ICP) as well as GPC/refractive index (RI) detection. All samples of food-grade carrageenan had a major broad peak of high molecular weight which eluted at around 6.5 min in both RI and ICP mode (sulphur and carbon), and each sample of them had no obvious peak of poligeenan (the detection limit was about 5%). The number average molecular weights of these carrageenans ranged from 193 kDa to 324 kDa, and the weight average molecular weights ranged from 453 kDa to 652 kDa based on RI data. Some samples had a few minor peaks which eluted around 10-12 min. These peaks came from ionic sulphate, sucrose or glucose. It was considered that if the data-sampling programme was improved, the GPC/ICP system would become a more powerful technique for evaluation of carrageenan samples containing ionic substances and sugar.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.