Four cases of annular pancreas diagnosed by endoscopic retrograde cholangiopancreatography (ERCP) are described and 105 cases of this anomaly in adults in Japan were reviewed. Among 105 cases, abdominal pain was the most frequent symptom. Concerning associated diseases, peptic ulcer was present in 24.8% and pancreatitis in 13.3%. In case 1, duodenal ulcer and pancreatic cyst were noted. Pancreatolithiasis was found in two cases (case 1 and 2). Case 4 presented the clinical features of acute pancreatitis. Out of 105 cases, well-described 26 were divided into six types. The following results were obtained. 1) The most frequent type was that in which the annular duct arose from the duct of Wirsung. 2) The next most frequent type was that in which the main pancreatic duct encircled the duodenum. 3) The other types corresponded to those in which the annular duct arose from the duct of Santorini and the common bile duct. We emphasized that ERCP is the most important procedure to find the characteristic features and to establish the therapeutic strategy in cases of annular pancreas.
Anti-thyroglobulin IgG in urine of patients with Graves' disease and chronic thyroiditis and healthy subjects was measured by a sensitive enzyme immunoassay (immune complex transfer enzyme immunoassay). Anti-thyroglobulin IgG in dialyzed urine was reacted simultaneously with 2,4-dinitrophenylated thyroglobulin and thyroglobulin-beta-D-galactosidase conjugate. The immune complex formed consisting of the three components was trapped onto polystyrene balls coated with (anti-2,4-dinitrophenyl group) IgG, eluted with epsilon N-2,4-dinitrophenyl-L-lysine, and transferred onto polystyrene balls coated with (anti-human IgG gamma-chain) IgG. beta-D-Galactosidase activity bound to the last polystyrene balls was assayed by fluorometry. Anti-thyroglobulin IgG was detected in most of the patients, but not in most of the healthy subjects; levels of anti-thyroglobulin IgG in urine of the patients were well correlated to those in serum of the same patients. The measurement of anti-thyroglobulin IgG in urine by the immune complex transfer enzyme immunoassay was suggested to be useful as a diagnostic aid for autoimmune thyroid diseases. The conventional standard ELISA was not sufficiently sensitive for measuring anti-thyroglobulin IgG in urine.
Previously, antithyroglobulin IgG was assayed in dialyzed urine from patients with autoimmune thyroid diseases by a sensitive enzyme immunoassay (immune complex transfer enzyme immunoassay), and most of the assay results were useful as a diagnostic aid for autoimmune thyroid diseases. However, dialysis of urine was laborious and time-consuming, and some results were less reliable due to low levels of anti-thyroglobulin IgG in urine. This paper describes some improvements of the assay. Useful assay results could be obtained for most of urine samples without dialysis, although some interfering substance(s) was suggested to be present in some urine samples before dialysis. Accurate assay results with no interference could be obtained after gel filtration by only two min centrifugation in place of dialysis. More reliable assay results for urine samples containing low levels of antithyroglobulin IgG were obtained after concentration using a molecular sieve.
A noncompetitive enzyme immunoassay (hetero-two-site enzyme immunoassay) for gamma 2-melanocyte-stimulating hormone (gamma 2-MSH) was developed. gamma 2-MSH (1-12) was biotinylated, trapped onto an anti-gamma 2-MSH (1-12) IgG-coated polystyrene bead, eluted at pH 1 after washing to eliminate other biotinylated substances, and measured using two streptavidin-coated polystyrene beads and affinity-purified anti-gamma 2-MSH (1-12) Fab'-peroxidase conjugate. The detection limit of gamma 2-MSH (1-12) was 10-30 amol (16-48 fg)/assay and 130-400 fmol (210-630 pg)/L of plasma. There was little or only slight cross reaction with alpha-MSH, beta-MSH, and gamma 1-MSH. By this immunoassay, the concentration and molecular size of immunoreactive gamma 2-MSH in plasma of healthy subjects were examined, and the results were compared with those by competitive enzyme immunoassay. Immunoreactive gamma 2-MSH measured by competitive enzyme immunoassay was a mixture of substances with high molecular weights (100-500 kDa), and its concentration was calculated to be 50-60 pmol/L using gamma 2-MSH (1-12) as standard. Immunoreactive gamma 2-MSH detected by the noncompetitive enzyme immunoassay after removal of high molecular weight substances was not homogeneous and smaller than gamma 2-MSH (1-12), and its concentration was approximately 1 pmol/L. The exact nature of these immunoreactive gamma 2-MSHs remains to be elucidated. gamma 2-MSH (1-12) added to plasma was degraded rapidly, and the concentration of gamma 2-MSH (1-12) was very low, if any, in plasma of healthy subjects.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.